PEPPERL+FUCHS Z778 Zener Barrier
PEPPERL+FUCHS Z778 Zener Barrier
PEPPERL+FUCHS Z778 Zener Barrier
PEPPERL+FUCHS Z778 Zener Barrier
PEPPERL+FUCHS Z778 Zener Barrier
PEPPERL+FUCHS Z778 Zener Barrier
PEPPERL+FUCHS Z778 Zener Barrier
PEPPERL+FUCHS Z778 Zener Barrier

PEPPERL+FUCHS Z778 Zener Barrier

MOQ : 1 Piece

PEPPERL+FUCHS Z778 Zener Barrier Specification

  • Frequency
  • DC to 60 Hz
  • Features
  • Reverse Polarity Protection, LED Indicator, Explosion Protection, Galvanic Isolation
  • Connectivity Type
  • Screw Terminals
  • Weight
  • Approx. 110 g
  • Phase
  • Single Channel
  • Control Type
  • Zener Diode Protection
  • Cable Length
  • Depends on Installation
  • IP Rating
  • IP20
  • Application
  • Intrinsic Safety Isolation for Hazardous Areas
  • Load Capacity
  • Up to 300 mA
  • Mounting Type
  • DIN Rail or Surface Mount
  • Automation Grade
  • Manual
  • Material
  • Metal Housing, Epoxy Sealed Module
  • Power
  • Passive-no external power required
  • Temperature
  • -20C to +60C
  • Voltage
  • Up to 28 V DC
  • Endress+Hauser Compatible
  • Yes
  • Typical Applications
  • Sensor Signal Transmission, Hazardous Area Field Instrumentation
  • Number of Channels
  • 2
  • Compliance
  • EN 60079-11, EN 61326-3-1 (EMC requirements for functional safety)
  • Fuse Rating
  • 50 mA for each channel
  • Max. Forward Voltage Drop
  • Approx. 1 V
 

PEPPERL+FUCHS Z778 Zener Barrier Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About PEPPERL+FUCHS Z778 Zener Barrier

PEPPERL+FUCHS Z778 Zener Barrier


2 Channel Zener Barrier with Analogue Output, 250 V max, 46mA max P&F Dual Channel Zener Diode Barriers Using a dual channel barrier impedes a direct grounding of the intrinsically safe circuit. The ground is only made in the event of a failure, if the zener diodes conduct.



Intrinsic Safety for Hazardous Areas

The PEPPERL+FUCHS Z778 Zener Barrier ensures safe operation of sensor and field instruments within hazardous environments by limiting energy transfer through its dual-channel, zener diode protection. Compliance with international safety (EN 60079-11) and EMC (EN 61326-3-1) standards ensures reliable performance in industrial settings where explosion protection is paramount.


Flexible Installation & Durable Construction

With a compact, epoxy-sealed metal housing and IP20 rating, this module is built for longevity and resilience. Its versatile design allows mounting on standard DIN rails or directly onto surfaces, and screw terminal connections simplify wiring. The Z778 is suitable for a broad range of applications, from hazardous area automation to sensor signal isolation.


Passive Operation and Wide Compatibility

The Z778 operates without any external power supply, making it inherently reliable for continuous use in demanding environments. Its compatibility with Endress+Hauser products and wide input range support diverse field applications, providing peace of mind and easy integration in new or existing system installations.

FAQ's of PEPPERL+FUCHS Z778 Zener Barrier:


Q: How does the PEPPERL+FUCHS Z778 Zener Barrier provide intrinsic safety in hazardous areas?

A: The Z778 Zener Barrier limits the energy (current and voltage) delivered to hazardous area equipment, preventing ignition risks. Its dual-channel design, with a maximum forward voltage drop of around 1 V and fused at 50 mA per channel, ensures safe operation, meeting the requirements for intrinsic safety as per EN 60079-11.

Q: What are the typical applications for the Z778 Zener Barrier?

A: Common applications include sensor signal transmission and isolation for hazardous area field instrumentation, such as process control systems or automation equipment, where intrinsic safety and explosion protection are essential.

Q: When should I use a passive Zener Barrier rather than an active isolator?

A: Use the Z778 passive Zener Barrier if your application requires reliable, low-maintenance intrinsic safety with no need for additional power supply. It is ideal for straightforward, cost-effective protection in signal transmission scenarios, especially where power constraints exist.

Q: Where can the Z778 Zener Barrier be installed?

A: The Z778 can be DIN rail mounted or surface mounted within control panels or enclosures that are in or near potentially explosive atmospheres. Its IP20-rated, epoxy-sealed metal housing provides environmental protection for typical industrial installations.

Q: What is the process for connecting field devices to the Z778 Zener Barrier?

A: Simply connect the field device wiring to the barrier's screw terminals, ensuring correct channel utilization for each sensor or instrument. The module requires no external power. It's suitable for both sensor input and output signals within the specified voltage and current ratings.

Q: How does the LED indicator on the Z778 benefit users?

A: The integrated LED indicator provides immediate visual feedback on the operational status of the barrier, helping maintenance personnel quickly identify normal operation or potential issues, thus reducing downtime and facilitating efficient troubleshooting.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPER FUCHS Category

PEPPERL+FUCHS KFD2-WAC-Ex1

PEPPERL+FUCHS KFD2-WAC-Ex1

Minimum Order Quantity : 1 Piece

Material : Polycarbonate housing

Application : Signal isolation and conversion in hazardous areas

Mounting Type : DIN rail

Automation Grade : Automatic

Control Type : Electronic

PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module

PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module

Minimum Order Quantity : 1 Piece

Material : Aluminum enclosure, polyamide terminal block

Application : Intrinsic safety interface for hazardous areas (sensor signal conditioning, PLC/DCS input protection)

Mounting Type : 35 mm DIN rail (EN 50022)

Automation Grade : Industrial

Control Type : Passive barrier

Pepper Fuchs Kfa6-str-124.500 46544

Pepper Fuchs Kfa6-str-124.500 46544

Material : Plastic Housing

Application : Intrinsic Safety Interface

Mounting Type : DIN Rail

Automation Grade : High

Control Type : Signal Conditioning

Pepper Fuchs Kfd2-cr-ex1.30-200 116313

Pepper Fuchs Kfd2-cr-ex1.30-200 116313

Material : Plastic

Application : Intrinsic Safety Barrier

Mounting Type : DIN Rail

Automation Grade : Industrial

Control Type : Electrical



Back to top