PEPPERL+FUCHS KFD2-WAC-Ex1
PEPPERL+FUCHS KFD2-WAC-Ex1
PEPPERL+FUCHS KFD2-WAC-Ex1
PEPPERL+FUCHS KFD2-WAC-Ex1
PEPPERL+FUCHS KFD2-WAC-Ex1
PEPPERL+FUCHS KFD2-WAC-Ex1
PEPPERL+FUCHS KFD2-WAC-Ex1
PEPPERL+FUCHS KFD2-WAC-Ex1

PEPPERL+FUCHS KFD2-WAC-Ex1

MOQ : 1 Piece

PEPPERL+FUCHS KFD2-WAC-Ex1 Specification

  • IP Rating
  • IP20
  • Control Type
  • Electronic
  • Weight
  • Approx. 150 g
  • Phase
  • Single Phase
  • Application
  • Signal isolation and conversion in hazardous areas
  • Automation Grade
  • Automatic
  • Connectivity Type
  • Screw terminal connection
  • Remote Control
  • Yes
  • Load Capacity
  • Up to 40 mA per channel
  • Mounting Type
  • DIN rail
  • Cable Length
  • Depends on installation
  • Frequency
  • 50/60 Hz
  • Features
  • 1-channel isolated barrier for safety applications, SIL 2 (IEC 61508), current and voltage input, relay output, highly accurate signal transmission, certified for use in hazardous areas, compact design
  • Material
  • Polycarbonate housing
  • Power
  • 1.9 W
  • Temperature
  • -20°C to +60°C
  • Voltage
  • 20 to 30 V DC
  • Mounting width
  • 20 mm
  • Output Signal
  • Relay
  • Approval
  • ATEX, IECEx, CSA, FM
  • Explosion Protection
  • II (1)G [Ex ia Ga] IIC
  • Response Time
  • <10 ms
  • Electromagnetic Compatibility
  • EN 61326-1
  • Model Number
  • KFD2-WAC-Ex1
  • Input Signal
  • 0/4...20 mA or 0/2...10 V
  • Operating Humidity
  • Up to 95% non-condensing
 

PEPPERL+FUCHS KFD2-WAC-Ex1 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About PEPPERL+FUCHS KFD2-WAC-Ex1

PEPPERL+FUCHS KFD2-WAC-Ex1

PEPPERL+FUCHS KFD2-WAC-EX1 SIGNAL CONVERTER
PEPPERL+FUCHS
K-SERIES
TRANSFORMER ISOLATED STRAIN GAUGE AMPLIFIER
TRANSMITTER
PART NO: 71894
TYPE: KFD2-WAC-EX1

MAX. AMBIENT TEMPERATURE 60C
UM= 250V
UN= 40V
U MAX OUT 17.6V
I MAX OUT 314MA



Advanced Signal Isolation for Safety

The KFD2-WAC-Ex1 provides essential isolation between hazardous and non-hazardous environments, protecting control systems from electrical surges. By supporting both current and voltage inputs and converting them via relay, this unit significantly enhances operational safety and system integrity, especially in sensitive process industries.


Reliable Performance in Extreme Conditions

Built with a polycarbonate housing, the KFD2-WAC-Ex1 operates reliably within tough temperature ranges from -20C to +60C and up to 95% non-condensing humidity. Its robust design, cutting-edge electromagnetic compatibility (EN 61326-1), and explosion protection certifications establish it as an excellent choice for harsh industrial settings.

FAQs of PEPPERL+FUCHS KFD2-WAC-Ex1:


Q: How does the KFD2-WAC-Ex1 enhance safety in hazardous areas?

A: This isolated barrier meets strict safety standards including ATEX, IECEx, CSA, FM, and SIL 2 (IEC 61508), allowing the safe transmission and isolation of signals between hazardous zones and control systems. Its relay output and rapid response time of less than 10 ms further reinforce protection and reliability in safety-critical applications.

Q: What input and output signals does the KFD2-WAC-Ex1 support?

A: The module accepts 0/4...20 mA or 0/2...10 V input signals and offers a relay output for interfacing with other control or automation devices. This flexibility enables seamless integration into diverse process control setups requiring precise signal conversion and output.

Q: When should I use the KFD2-WAC-Ex1 in my control systems?

A: Utilize the KFD2-WAC-Ex1 whenever you need secure signal isolation and conversion within hazardous locations, particularly where explosion-proof processes and high accuracy are vital. Its suitable for safety-related and automatic control systems that demand dependable protection and compliance.

Q: Where can the KFD2-WAC-Ex1 be installed for optimum performance?

A: Designed for DIN rail mounting, the KFD2-WAC-Ex1 fits easily within industrial control panels in hazardous or non-hazardous areas. Its compact size (20 mm width) and weight (approximately 150 g) offer straightforward installation, benefiting distributors, integrators, and service providers alike.

Q: What is the process for connecting the KFD2-WAC-Ex1 in a system?

A: Connection is accomplished using screw terminal connectors. Ensure the unit receives 20 to 30 V DC power, and connect input/output cables as per system requirements. The cable length can vary depending on installation parameters, and the unit supports single-phase, 50/60 Hz operation without remote control capability.

Q: How does the KFD2-WAC-Ex1 benefit system reliability and accuracy?

A: With precise signal transmission, high load capacity (up to 40 mA per channel), and electromagnetic compatibility (EN 61326-1), the KFD2-WAC-Ex1 improves overall system stability and accuracy. Its safety certifications ensure compliance while protecting personnel and assets in demanding automation environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPER FUCHS Category

PEPPERL+FUCHS KHA6-RW1/Ex1

PEPPERL+FUCHS KHA6-RW1/Ex1

Material : Plastic

Remote Control : Yes

Voltage : Not Available

Connectivity Type : Not Available

Automation Grade : Not Available

Pepperl Fuchs Kfd0-tr-ex1

Pepperl Fuchs Kfd0-tr-ex1

Minimum Order Quantity : 1 Piece

Material : FIBER

Remote Control : Yes

Voltage : 18~30 VDC

Connectivity Type : Terminal Blocks

Automation Grade : Automatic

PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module

PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module

Minimum Order Quantity : 1 Piece

Material : Aluminum enclosure, polyamide terminal block

Remote Control : Yes

Voltage : 28 V DC (max via zener diodes)

Connectivity Type : Screw terminals

Automation Grade : Industrial

PEPPERL+FUCHS KFD2-PT2-Ex1 ISOLATED BARRIER

PEPPERL+FUCHS KFD2-PT2-Ex1 ISOLATED BARRIER

Material : Plastic

Remote Control : Yes

Voltage : 24V DC

Connectivity Type : Wired

Automation Grade : High



Back to top