PEPPERL+FUCHS Z715 Zener Barrier Specification

  • Remote Control
  • Yes
  • Application
  • Intrinsic Safety Barrier for Hazardous Areas
  • Control Type
  • Zener Diode Clamp, Passive
  • Mounting Type
  • DIN Rail Mountable
  • Frequency
  • DC Signals (suitable for analog transmitters, switches)
  • Features
  • Galvanic Isolation, Explosion Protection, LED Indicator for Fault
  • Connectivity Type
  • Screw Terminals
  • Sensor Type
  • Compatible with 2-wire transmitters, switches
  • IP Rating
  • IP20
  • Automation Grade
  • Industrial
  • Load Capacity
  • Maximum 93 mA
  • Weight
  • Approximately 100 g
  • Phase
  • N/A (DC Operation)
  • Material
  • Plastic Housing, Electronic Components
  • Power
  • No External Power Required (Passive Device)
  • Temperature
  • -20C to +60C Operating Range
  • Voltage
  • 28 V DC Max (Zener Clamping Voltage)
  • Mounting Position
  • Any
  • Approvals/Certification
  • ATEX, IECEx, FM, CSA for Intrinsic Safety
  • Polarity
  • Polarity Dependent
  • Dimensions (W x H x D)
  • 12.5 mm x 115 mm x 103 mm
  • Short Circuit Current
  • ~93 mA
  • Max. Series Resistance
  • 300 Ohms (typical)
  • Model
  • Z715
  • Number of Channels
  • Single Channel
 

PEPPERL+FUCHS Z715 Zener Barrier Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About PEPPERL+FUCHS Z715 Zener Barrier

PEPPERL+FUCHS Z715 Zener Barrier


Pepperl+Fuchs Z715 Zener Barrier. 1-channel, DC version, positive polarity, Working voltage 13 V at 10 A, Series resistance max. 107 , Fuse rating 100 mA, DIN rail mountable, Type: DC version, positive polarity.



Intrinsic Safety for Hazardous Environments

The Z715 Zener Barrier ensures safe operation of electrical equipment in explosive atmospheres by limiting voltage and current. Its certification for ATEX, IECEx, FM, and CSA standards makes it suitable for use in industries like oil and gas, chemical processing, and manufacturing, where intrinsic safety is mandatory to prevent ignition of flammable gases or dust.


Reliable Passive Protection

Utilizing a Zener diode clamp mechanism, the Z715 offers a purely passive form of intrinsic safety, meaning it does not require external power to function. The device's robust build and plastic housing ensure reliable protection and durability, while the integrated LED indicator provides immediate fault notification for quick troubleshooting.


Easy Installation and Versatile Mounting

Designed for convenience, the Z715 barrier comes with screw terminal connectivity and is DIN rail mountable. Its compact dimensions allow installation in space-constrained panels. The flexible mounting position and IP20 rating streamline deployment and ongoing maintenance in industrial control systems.

FAQ's of PEPPERL+FUCHS Z715 Zener Barrier:


Q: How does the Z715 Zener Barrier enhance safety in hazardous areas?

A: The Z715 Zener Barrier limits voltage and current to prevent sparks or excessive heat, ensuring that devices connected in hazardous areas remain intrinsically safe. Its ATEX, IECEx, FM, and CSA certifications provide assurance for use in explosive environments.

Q: What processes is the Z715 suitable for in industrial settings?

A: The Z715 barrier is ideal for protecting DC signal lines from analog transmitters and switches, which are commonly found in process control, automation, and monitoring systems in industries such as oil, gas, chemical, and pharmaceutical production.

Q: When should I use a Zener barrier like the Z715 instead of other protection types?

A: You should use a Zener barrier like the Z715 when working with intrinsically safe circuits in hazardous locations, particularly where passive, maintenance-free operation is preferred and galvanic isolation is beneficial to prevent unwanted energy transfer.

Q: Where can the Z715 be mounted, and what are its installation benefits?

A: The Z715 can be mounted on a DIN rail in any orientation, saving space in standard industrial enclosures. Its compact size, plastic housing, and screw terminal connectors simplify installation and integration into new or existing systems.

Q: What are the main benefits of using the Z715 Zener Barrier in my control system?

A: Using the Z715 enhances operational safety, provides explosion protection, requires no external power, and features an LED fault indicator for rapid diagnostics. Its approvals and rugged design ensure long-term reliability in demanding environments.

Q: How do I connect field devices to the Z715 Zener Barrier?

A: Field devices such as 2-wire transmitters and switches are wired directly to the screw terminal connections of the Z715. Its polarity-dependent design ensures correct circuit protection, while compatibility with DC signals streamlines field device integration.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPER FUCHS Category

PEPPERL+FUCHS KFD2-DW-Ex1D

PEPPERL+FUCHS KFD2-DW-Ex1D

Minimum Order Quantity : 1 Piece

Material : Plastic / Electronic components

Automation Grade : Automatic

Application : Intrinsically safe proximity sensors signal isolator for hazardous areas

Control Type : Digital

Mounting Type : DIN Rail Mounting

PEPPERL+FUCHS KFD2-CR-Ex1 30-200

PEPPERL+FUCHS KFD2-CR-Ex1 30-200

Minimum Order Quantity : 1 Piece

Material : Polycarbonate housing

Automation Grade : Industrial Grade

Application : Signal isolation and relay control in hazardous areas

Control Type : Relay Control Module

Mounting Type : 35 mm DIN rail mounting

PEPPERL+FUCHS KFD2-PT2-Ex1 ISOLATED BARRIER

PEPPERL+FUCHS KFD2-PT2-Ex1 ISOLATED BARRIER

Material : Plastic

Automation Grade : High

Application : Industrial Automation

Control Type : Electronic

Mounting Type : DIN Rail Mount

PEPPERL+FUCHS KFD2-SH-Ex1

PEPPERL+FUCHS KFD2-SH-Ex1

Material : Plastic Housing

Automation Grade : Industrial

Application : Intrinsic Safety Module

Control Type : Signal Conditioner

Mounting Type : DIN Rail Mounting



Back to top