LT MC61A OVER CURRENT EARTH FAULT RELAY
LT MC61A OVER CURRENT EARTH FAULT RELAY
LT MC61A OVER CURRENT EARTH FAULT RELAY
LT MC61A OVER CURRENT EARTH FAULT RELAY
LT MC61A OVER CURRENT EARTH FAULT RELAY
LT MC61A OVER CURRENT EARTH FAULT RELAY
LT MC61A OVER CURRENT EARTH FAULT RELAY
LT MC61A OVER CURRENT EARTH FAULT RELAY

LT MC61A OVER CURRENT EARTH FAULT RELAY

MOQ : 1 Piece

LT MC61A OVER CURRENT EARTH FAULT RELAY Specification

  • Ambient Temperature
  • -10C to +55C
  • Contact Resistance
  • <50 m
  • Protect Feature
  • Over-current and Earth-fault protection
  • Coil Power
  • <5VA
  • Contact Form
  • 1 NO + 1 NC
  • Mechanical Life
  • 1 Million Operations
  • Power Consumption
  • <5VA
  • Contact Material
  • Silver Alloy
  • Coil Voltage
  • 230V AC
  • Dielectiric Strength
  • 2KV for 1 min
  • Working Temperature
  • -10C to +55C
  • Product Type
  • Over Current Earth Fault Relay
  • Insulation Resistance
  • >100 M at 500V DC
  • Theory
  • Electromagnetic Relay
  • Usage
  • Protection for electrical circuits against over current and earth fault
  • Contact Load
  • 5A at 250V AC
  • Operate Time
  • 0.1 - 1 Sec (Adjustable)
  • Terminal Type
  • Screw Terminal
  • Rated Voltage
  • 230V AC
  • Supply Terminal
  • Bottom/Rear
  • Size
  • Standard Panel Mount
  • Color
  • Black and White
  • Dimension (L*W*H)
  • 95mm x 96mm x 110mm
  • Weight
  • Approx. 350g
  • Display
  • LED Indication for Trip, Power and Fault
  • Application
  • Feeder/Distribution Circuit Protection
  • Setting Range
  • Overcurrent: 50%-200%, Earth Fault: 10%-80%
  • Humidity
  • Up to 90% RH (non-condensing)
  • Adjustment
  • Potentiometer based
  • Enclosure Material
  • ABS Plastic
  • IP Rating
  • IP20
  • Frequency
  • 50/60 Hz
  • Mounting Type
  • Panel Mount
  • Response Time
  • Less than 40 ms
  • Reset Type
  • Manual/Automatic
  • Tripping Characteristics
  • Definite time tripping
 

LT MC61A OVER CURRENT EARTH FAULT RELAY Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About LT MC61A OVER CURRENT EARTH FAULT RELAY

LT MC61A OVER CURRENT EARTH FAULT RELAY

Description

You have been looking for the best Over Current and Earth Fault Relay from top dealers Dont look any further because at LTSuFin you can find the best brands for Over Current and Earth Fault Relay at best price in India Buy Over Current and Earth Fault Relay online on Indias leading marketplace for industrial tools construction materials electrical and equipment Expect high quality from top suppliers for high performance and great durability We offer you Over Current and Earth Fault Relay at genuine wholesale rates with great discounts and avail quotations for bulk purchases Request Quotations for Over Current and Earth Fault Relay from verified sellers and benefit from avail Logistics and Financing options

Specifications
  • Current Range :1 5 A
  • Earth Fault Setting :05 2 A
  • Brand:LT
  • Model No :MC61ANX
  • Trip Time Delay :01 1 sec
  • Rated Voltage :Upto 240 V
  • CT Ratio :8005 A
  • Accuracy: 1
  • Mounting Type :DIN Rail
  • Body Material :Polycarbonate


Comprehensive Protection for Electrical Circuits

The LT MC61A relay is engineered to ensure the safety and reliability of electrical systems by detecting overcurrent and earth fault conditions promptly. Equipped with adjustable settings and fast tripping, it helps prevent damage to equipment, reducing downtime and maintenance costs for industrial users.


Intuitive Operation and User-Friendly Design

This relay features effective manual and automatic reset capabilities, potentiometer-based adjustment for easy setting, and clear LED indication for trip, power, and fault statuses. Its panel-mount construction, screw terminals, and standard dimensions simplify installation and integration into existing systems.


Durability and Consistency in Performance

Manufactured with high-grade ABS plastic and reliable silver alloy contacts, the LT MC61A ensures consistent operation across a wide temperature and humidity range. Its robust design makes it suitable for challenging industrial environments while maintaining an extensive operational lifespan.

FAQ's of LT MC61A OVER CURRENT EARTH FAULT RELAY:


Q: How does the LT MC61A relay provide protection against overcurrent and earth faults?

A: The LT MC61A continuously monitors circuit conditions. If it detects current levels exceeding set thresholds (overcurrent: 50%-200%, earth fault: 10%-80%), the relay trips within 0.1-1 seconds (user adjustable), effectively isolating the fault to protect equipment and prevent outages.

Q: What is the process for adjusting the trip settings and response times?

A: Trip settings for both overcurrent and earth fault are adjusted using built-in potentiometers on the relay, allowing easy tuning within specified ranges. The response time can also be set between 0.1 and 1 second to customize protection to application needs.

Q: When should the manual or automatic reset feature be used?

A: Manual reset is ideal for situations where inspection or troubleshooting is necessary after a trip, while automatic reset is useful for remote or unmanned installations where maintenance access is limited and fast restoration is required.

Q: Where should the LT MC61A relay be installed in an electrical circuit?

A: Designed for panel mounting, the LT MC61A should be installed in feeder or distribution circuit panels, ensuring effective protection at points where overcurrent or earth fault could damage system components or disrupt operations.

Q: What are the advantages of LED indication on this relay?

A: The LED indicators provide real-time status for trip, power, and fault, offering instant visual feedback to operators and maintenance personnel. This feature streamlines monitoring and troubleshooting, reducing response time during faults.

Q: How does the enclosure and build quality enhance reliability?

A: With a tough ABS plastic enclosure rated at IP20 and the capability to resist up to 90% relative humidity, the relay stands up to harsh industrial environments. Superior insulation resistance and low contact resistance further contribute to long-term reliability.

Q: What are the key benefits of using the LT MC61A relay in my distribution panel?

A: Using the LT MC61A relay ensures fast and precise protection against both overcurrent and earth fault, minimizes potential equipment damage, offers user-friendly adjustments, and provides durability with over one million mechanical operations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

ABB REU610CVVHCNR RELAY

ABB REU610CVVHCNR RELAY

Minimum Order Quantity : 1 Piece

Color : Grey

Product Type : Protection Relay

Usage : Protection and control of electrical power systems

Power Consumption : Max. 10 W

SIEMENS 7UM6221-5EB92-3CA0/FF (BF1012106579) GENERATOR PROTECTION RELAY

SIEMENS 7UM6221-5EB92-3CA0/FF (BF1012106579) GENERATOR PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Color : Grey

Product Type : Generator Protection Relay

Usage : Generator Protection

Power Consumption : 40 VA

ALLEN BRADLEY 700-FSM4UU23 TIMING RELAY

ALLEN BRADLEY 700-FSM4UU23 TIMING RELAY

Minimum Order Quantity : 1 Piece

Color : Grey

Product Type : Multifunction Timing Relay

Usage : Industrial Automation, Timer Control Applications

Power Consumption : <2 VA

MICOM P442311B2M0360J PROTECTION RELAY

MICOM P442311B2M0360J PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Color : Grey

Product Type : Numerical Protection Relay

Usage : Feeder, Transformer, and Generator Protection

Power Consumption : < 25 VA



Back to top