SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY Specification

  • Contact Form
  • Form C (changeover contact)
  • Contact Material
  • AgCdO/AgNi
  • Power Consumption
  • < 30 W
  • Working Temperature
  • -5C to +55C
  • Ambient Temperature
  • -5C to +55C (operation), -25C to +70C (storage)
  • Coil Voltage
  • Not applicable (electronic relay)
  • Contact Resistance
  • < 100 m
  • Dielectiric Strength
  • 2.0 kV RMS, 50/60 Hz, 1 min
  • Mechanical Life
  • >10 million operations
  • Coil Power
  • Not applicable (electronic relay)
  • Protect Feature
  • Differential, Overcurrent, Earth Fault, Loss of Excitation, Over/Under Voltage, Frequency Protection, Reverse Power, Vector Surge, Phase Balance, Overload protection
  • Product Type
  • Digital Generator Protection Relay
  • Insulation Resistance
  • >100 M at 500 V DC
  • Theory
  • Microprocessor based digital relay
  • Usage
  • Generator Protection
  • Contact Load
  • DC side: 30 V / 6 A; AC side: 250 V / 8 A (resistive load)
  • Operate Time
  • Fast response, typically < 20 ms depending on function
  • Terminal Type
  • Screw-type terminals
  • Rated Voltage
  • 110-250 V AC/DC (universal auxiliary supply voltage)
  • Supply Terminal
  • Rear terminal block
  • Size
  • 1/2 19-inch, 4U
  • Color
  • Grey/Black front panel
  • Dimension (L*W*H)
  • 192 mm x 177 mm x 293 mm
  • Weight
  • Approx. 5 kg
  • Firmware Upgradable
  • Yes, via front interface or communication port
  • Display
  • LCD, multi-line, with LED indicators
  • Model
  • 7UM6221-2EB92-0AC0/FF (BF1110052222)
  • Trip Circuit Supervision
  • Yes, integrated
  • Standards Compliance
  • IEC 60255, IEC 61000-4-x (EMC), IEEE C37.90
  • Redundancy
  • Redundant DC supply inputs (optional)
  • Rated Frequency
  • 50/60 Hz
  • Analog Inputs
  • 4 to 8 (configurable)
  • Number of Binary Outputs
  • 11
  • Interface Communication
  • RS485, Ethernet (IEC 61850, IEC 60870-5-103 protocols)
  • Event Recording
  • Yes, with time tagging (1 ms) and disturbance recorder
  • Family
  • SIPROTEC 4 series
  • Number of Binary Inputs
  • 16
  • Housing Protection
  • IP54 (front), IP20 (rear)
  • Mounting Method
  • Panel flush mounting
 

SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY

SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY


The SIPROTEC 4 7UM62 protection relay is a compact unit which has been specially developed and designed for the protection of small, medium-sized and large generators.



Advanced Generator Protection and Monitoring

Experience state-of-the-art generator safeguarding with the SIEMENS 7UM6221-2EB92-0AC0/FF relay. Its adaptable configuration, including various protection features such as differential and overcurrent protection, ensures optimized security for power systems. Real-time disturbance recording and precise event tagging aid in accurate diagnostics and streamlined system management, making it ideal for modern substations and power plants.


Reliable Communication and Easy Integration

Seamlessly integrate the relay into your existing infrastructure with robust communication options, including RS485 and Ethernet interfaces supporting IEC 61850 and IEC 60870-5-103 protocols. This ensures compatibility with SCADA and other digital monitoring systems, providing remote access, control, and data acquisition capabilities vital for operational efficiency.


Durable Design for Tough Environments

Built for durability, the relay is enclosed in an IP54 (front) and IP20 (rear) housing, providing solid protection against dust and water ingress. Wide operational and storage temperature ranges, high dielectric strength, and extensive mechanical life surpassing 10 million operations guarantee dependable performance in demanding industrial conditions.

FAQ's of SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY:


Q: How do I upgrade the firmware of the SIEMENS 7UM6221-2EB92-0AC0/FF relay?

A: Firmware upgrades can be performed via the front interface or a communication port (RS485 or Ethernet). This allows you to keep the relay updated with the latest features and security patches, ensuring reliable performance and compatibility with evolving system requirements.

Q: What protection features does this generator relay provide?

A: The relay offers comprehensive protection including differential, overcurrent, earth fault, loss of excitation, over/under voltage, frequency, reverse power, vector surge, phase balance, and overload protection, making it suitable for complex generator safety applications.

Q: When should I use the redundancy feature for DC supply inputs?

A: Redundant DC supply inputs are recommended for applications requiring high system availability. Using the redundancy option ensures continuous operation even if one DC supply fails, minimizing downtime and enhancing operational security.

Q: Where can the SIEMENS 7UM6221-2EB92-0AC0/FF be installed?

A: The relay is designed for panel flush mounting and is suitable for use in power plants, substations, and industrial generator rooms. Its robust housing and flexible connection terminals allow installation in diverse environments.

Q: What are the main benefits of its event and disturbance recording capabilities?

A: With event recording and disturbance logging at 1 ms accuracy, the relay provides precise historical data for analysis and troubleshooting. This enables timely detection of faults, root-cause identification, and improved service response times.

Q: How does the relay communicate with SCADA systems?

A: It communicates using RS485 and Ethernet interfaces, supporting industry protocols like IEC 61850 and IEC 60870-5-103. This facilitates seamless integration with SCADA platforms for remote monitoring, control, and data acquisition.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

ABB REU610CVVHCNR RELAY

ABB REU610CVVHCNR RELAY

Minimum Order Quantity : 1 Piece

Product Type : Protection Relay

Color : Grey

Theory : Other , Electromechanical

Usage : Protection and control of electrical power systems

MICOM P127 BA0F112BA OVERCURRENT PROTECTION RELAY

MICOM P127 BA0F112BA OVERCURRENT PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Product Type : Numerical Overcurrent Protection Relay

Color : White & Grey

Theory : Other , Microprocessor Based Protection Relay

Usage : Overcurrent Protection in electrical systems

SIEMENS  7SJ6612-5EB90-1HF0BB PROTECTION RELAY

SIEMENS 7SJ6612-5EB90-1HF0BB PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Product Type : Protection Relay

Color : Gray

Theory : Electrical System Protection, Other

Usage : Industrial Equipment Protection; Electrical Control Systems

VAMP 50 PROTECTION RELAY

VAMP 50 PROTECTION RELAY

Minimum Order Quantity : 1 Ampere

Product Type : Protection Relay

Color : Beige and Green

Theory : Other , Digital Protection Relay

Usage : Electrical power system protection



Back to top