SIEMENS 7SJ6005-5EA00-0DA0/BB
SIEMENS 7SJ6005-5EA00-0DA0/BB
SIEMENS 7SJ6005-5EA00-0DA0/BB
SIEMENS 7SJ6005-5EA00-0DA0/BB
SIEMENS 7SJ6005-5EA00-0DA0/BB
SIEMENS 7SJ6005-5EA00-0DA0/BB

SIEMENS 7SJ6005-5EA00-0DA0/BB

MOQ : 1 Ampere

SIEMENS 7SJ6005-5EA00-0DA0/BB Specification

  • Coil Power
  • < 1.2 VA
  • Contact Resistance
  • < 100 m
  • Working Temperature
  • -20C to +60C
  • Contact Form
  • 2 Changeover (DPDT)
  • Power Consumption
  • < 10 VA
  • Dielectiric Strength
  • 2 kV rms for 1 minute
  • Coil Voltage
  • 110/220 V AC
  • Contact Material
  • AgCdO
  • Mechanical Life
  • >1 x 10 operations
  • Protect Feature
  • Overcurrent, Earth Fault, and optional voltage protection
  • Ambient Temperature
  • -25C to +70C
  • Product Type
  • SIEMENS 7SJ6005-5EA00-0DA0/BB
  • Insulation Resistance
  • > 100 M at 500 V DC
  • Theory
  • Electromechanical relay with microprocessor-based protection
  • Usage
  • Protection and control device for electrical networks
  • Contact Load
  • 5 A at 250 V AC
  • Operate Time
  • < 15 ms
  • Terminal Type
  • Screw terminal
  • Rated Voltage
  • 220/230 V AC
  • Supply Terminal
  • Rear connection
  • Size
  • Standard compact relay size
  • Color
  • Grey
  • Dimension (L*W*H)
  • Approx. 240 x 106 x 220 mm
  • Weight
  • Approx. 2.8 kg
  • Communication Ports
  • RS485, USB, optionally Ethernet (IEC 61850)
  • Mounting Type
  • Flush mounting via panel cutout
  • Event Logging
  • 400 event memory (with time stamping)
  • Frequency Range
  • 45-65 Hz
  • Relay Functions
  • Overcurrent, Earth fault, Trip Circuit Supervision, Auto-recloser, Metering
  • Number of Outputs
  • 6 output relays
  • Metering Accuracy
  • Class 1.0
  • Memory
  • Non-volatile event and fault recording
  • Protection Class
  • IP54 (front) / IP20 (rear)
  • Display
  • LCD programmable
  • Setting Range
  • Adjustable via front keypad or software
  • Vibration Resistance
  • 5g, 10-150 Hz
  • Number of Inputs
  • 6 digital inputs
 

SIEMENS 7SJ6005-5EA00-0DA0/BB Trade Information

  • Minimum Order Quantity
  • 1 Ampere
  • Supply Ability
  • 100 Amperes Per Month
  • Delivery Time
  • 7 Days
 

About SIEMENS 7SJ6005-5EA00-0DA0/BB

NUMERICAL OVERCURRENT-TIME PROTECTION RELAY SIPROTEC 7SJ600 OVERLOAD PROTECTION, UNBALANCED-LOAD PROTECTION BINARY INPUT VOLTAGE:24 TO 250V WITH ISOLATED RS485 INTERFACE RATED CURRENT: 5A, 50/60HZ RATED AUXILIARY VOLTAGE FOR BUILT-IN CONVERTER DC 24, 48V IN 7XP20 CASE FOR PANEL FLUSH MOUNTING OR FOR CUBICLE MOUNTING OPERATOR LANGUAGE IN ENGLISH, GERMAN, SPANISH AND FRENCH WITHOUT RECLOSURE WITHOUT CONTROL.


Comprehensive Protection and Control

Engineered for diverse electrical applications, the SIEMENS 7SJ6005-5EA00-0DA0/BB relay provides powerful protection against overcurrent and earth faults, plus advanced features such as auto-recloser and trip circuit supervision. It efficiently records and manages network events, safeguarding assets and minimizing downtime during incidents.


Flexible Configuration and Communication

This relay supports flexible configuration through a front keypad or software, enabling precise adjustment for varied operational needs. With RS485, USB, and optional Ethernet interfaces (IEC 61850), it effortlessly integrates into new or existing automation and control systems.


Reliable Operation in Harsh Environments

Designed to withstand challenging industrial conditions, the device boasts high vibration resistance (5g), robust insulation, and operates reliably from -20C to +60C. Its IP54 front protection and compact build ensure longevity and integrity in dusty or wet locations.

FAQs of SIEMENS 7SJ6005-5EA00-0DA0/BB:


Q: How is the SIEMENS 7SJ6005-5EA00-0DA0/BB relay installed?

A: The device is designed for flush mounting via a panel cutout, using screw terminals for secure connections at the rear. Its standard compact size ensures a straightforward fit into most control panels.

Q: What digital communication options are available with this relay?

A: The relay is equipped with RS485 and USB as standard, and optionally supports Ethernet communication (IEC 61850) for seamless integration into substation automation and control systems.

Q: When should you use this relay for protection and control?

A: This relay is ideal for use in medium-voltage electrical networks requiring protection from overcurrent, earth faults, and voltage disturbances. It is also suitable where event and fault logging are essential for operations and maintenance.

Q: Where can the relays event history be viewed or retrieved?

A: Event history, including up to 400 timestamped records, can be accessed via the front LCD, the keypad, or downloaded using supporting Siemens software through the USB or communication ports.

Q: What is the process for adjusting the protection settings?

A: Settings can be modified using the front keypad located below the LCD display or by connecting to Siemens software through USB or RS485. The process allows real-time adjustments to protection parameters as operational requirements evolve.

Q: What are the main benefits of using this relay in electrical networks?

A: Key benefits include rapid operate time (<15 ms), detailed event and fault recording, highly accurate metering (Class 1.0), robust environmental resilience, and versatile communication for efficient diagnostics, control, and network reliability.

Q: How does the relay ensure data retention during power loss?

A: The relay is equipped with non-volatile memory, preserving all event and fault records even if power is lost, ensuring operators retain critical data for post-event analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

ABB REF615 PROTECTION RELAY

ABB REF615 PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Usage : Feeder protection applications

Working Temperature : 25C to +55C

Terminal Type : Other, Screw type

Color : Grey

Rated Voltage : 110240 V AC/DC

Shreem SPF-16T Series Automatic Power Factor Controller

Shreem SPF-16T Series Automatic Power Factor Controller

Minimum Order Quantity : 1 Piece

Usage : Automatic Power Factor Correction in LT panels

Working Temperature : 10C to +60C

Terminal Type : Other, Screw Type Terminal Blocks

Color : Grey/Black front panel

Rated Voltage : 415V AC

ALLEN BRADLEY 700-FSM4UU23 TIMING RELAY

ALLEN BRADLEY 700-FSM4UU23 TIMING RELAY

Minimum Order Quantity : 1 Piece

Usage : Industrial Automation, Timer Control Applications

Working Temperature : 20C to +55C

Terminal Type : Other, Screw Terminals

Color : Grey

Rated Voltage : 24240V AC/DC

SIEMENS 7UM6221-6EB92-3CA0/FF (BF1105147896) GENERATOR PROTECTION RELAY

SIEMENS 7UM6221-6EB92-3CA0/FF (BF1105147896) GENERATOR PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Usage : Generator Protection

Working Temperature : 10C to +60C

Terminal Type : Other, Screw Terminal

Color : Standard Siemens Grey

Rated Voltage : 110 V DC / 220 V DC / 100240 V AC Universal Power Supply



Back to top