ABB RER670 PROTECTION RELAY (ONLY DISPLAY)
ABB RER670 PROTECTION RELAY (ONLY DISPLAY)
ABB RER670 PROTECTION RELAY (ONLY DISPLAY)
ABB RER670 PROTECTION RELAY (ONLY DISPLAY)
ABB RER670 PROTECTION RELAY (ONLY DISPLAY)
ABB RER670 PROTECTION RELAY (ONLY DISPLAY)
ABB RER670 PROTECTION RELAY (ONLY DISPLAY)
ABB RER670 PROTECTION RELAY (ONLY DISPLAY)

ABB RER670 PROTECTION RELAY (ONLY DISPLAY)

MOQ : 1 Piece

ABB RER670 PROTECTION RELAY (ONLY DISPLAY) Specification

  • Coil Power
  • <1.7 W per coil
  • Power Consumption
  • <35 W (typical, depending on setup)
  • Contact Material
  • AgCdO / AgNi (silver alloy contacts)
  • Working Temperature
  • -40C to +70C (storage)
  • Dielectiric Strength
  • 2.0 kV RMS, 50 Hz, 1 min
  • Contact Form
  • SPDT or DPDT (configuration dependent)
  • Protect Feature
  • Overcurrent, distance, differential, voltage, frequency protection options
  • Ambient Temperature
  • -25C to +55C (operational)
  • Contact Resistance
  • <100 m
  • Coil Voltage
  • 24-250 V DC/AC universal
  • Mechanical Life
  • >10 million operations (per contact relay)
  • Product Type
  • Digital Protection Relay Display Unit
  • Insulation Resistance
  • >100 M at 500 V DC
  • Theory
  • Microprocessor based intelligent relay
  • Usage
  • Protection, control and monitoring of power systems
  • Contact Load
  • 8 A at 250 V AC / 30 V DC (resistive load)
  • Operate Time
  • <15 ms (typical depending on function configuration)
  • Terminal Type
  • Screw terminals (plug-in, removable type)
  • Rated Voltage
  • 24-250 V DC/AC (universal auxiliary voltage supply)
  • Supply Terminal
  • Rear and front connection options
  • Size
  • 4U height (19 rack mounting), 1/2 rack width
  • Color
  • Grey/White (Standard ABB relay enclosure)
  • Dimension (L*W*H)
  • W: 177 mm x H: 177 mm x D: 268 mm (typical, excluding connectors)
  • Weight
  • Approx. 6-7 kg (configuration dependent)
  • Display Type
  • High-resolution graphical LCD, multilingual interface
  • Time Synchronization
  • SNTP/NTP & IRIG-B supported
  • Mounting
  • Flush, wall or rack mounting options
  • Event Record Storage
  • Multiple fault event and disturbance records
  • EMC Compliance
  • IEC 60255-26, EN 61000-6-2 and 6-4
  • Communication
  • Multiple Ethernet ports, IEC 61850, Modbus, DNP3, 103 protocols supported
  • Protection Class
  • IP 40 (front), IP 20 (rear)
  • Data Logging
  • Extended sequence-of-events logging
  • Firmware Upgrade
  • Firmware upgradeable via front port or network
  • Shock & Vibration
  • IEC 60255-21-1/2/3 compliant
  • Configuration
  • Flexible, freely programmable logic and settings
  • HMI Controls
  • Front panel keypad, push-buttons and navigation keys
  • Relative Humidity
  • 5%-95% (non-condensing)
 

ABB RER670 PROTECTION RELAY (ONLY DISPLAY) Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ABB RER670 PROTECTION RELAY (ONLY DISPLAY)

ABB RER670 PROTECTION RELAY (ONLY DISPLAY)


ABBs railway application intelligent electronic device (IED), Relion RER670, is used for the protection, control and monitoring of the transmission lines and/or transformers in a two-phase 16.7, 50 and 60 Hz power system design for railway supply. It supports isolated, compensated and solidly earthed networks.



High-Resolution Display and Intuitive HMI

The RER670 relay features a vivid, high-resolution graphical LCD that supports a multilingual interface, making operation and monitoring straightforward for users of varying language backgrounds. The front panel is equipped with a keypad, push-buttons, and navigation keys, enabling efficient local control and fast access to essential settings and event records. This ensures optimal ease-of-use in on-site environments.


Comprehensive Communication Capabilities

Designed to seamlessly integrate into modern power systems, the RER670 supports a wide range of communication protocols including IEC 61850, Modbus, DNP3, and 103, as well as twice Ethernet ports. Flexible network compatibility and robust time synchronization (SNTP/NTP & IRIG-B) facilitate efficient, secure data exchange and grid-wide event coordination. This interoperability is vital for contemporary substations and grid applications.


Configurable and Reliable Protection

With freely programmable logic and settings, the RER670 allows tailored protection strategies, including overcurrent, distance, differential, voltage, and frequency options. Multiple fault event and disturbance records are stored for analysis, and the relay is compliant with high standards for EMC, insulation, shock, and vibration. Designed to operate in a wide temperature range with high mechanical durability, it offers reliability in demanding scenarios.

FAQ's of ABB RER670 PROTECTION RELAY (ONLY DISPLAY):


Q: How can I upgrade the firmware on the ABB RER670 Protection Relay?

A: Firmware can be upgraded on the ABB RER670 via the front communication port or over the network. This flexibility ensures minimal downtime and ensures the latest features and security enhancements are easily deployable.

Q: What are the main benefits of using the high-resolution graphical LCD display?

A: The high-resolution graphical LCD offers clear visibility of system information, supports multiple languages for user convenience, and simplifies navigation through event records, settings, and alarms using the front panel controls.

Q: When should I use the extended event and disturbance recording feature?

A: The extended event and disturbance recording is essential for post-fault analysis and system diagnostics. It captures and stores detailed records of multiple events, helping engineers and operators quickly determine root causes and implement preventive actions.

Q: Where can the ABB RER670 be mounted in a power system setup?

A: This relay offers flexible mounting options, allowing it to be installed flush on panels, attached to walls, or integrated into a standard 19-inch rack, accommodating a variety of substation and control room layouts.

Q: What communication protocols does the RER670 support for system integration?

A: The relay supports multiple protocols, including IEC 61850, Modbus, DNP3, and 103, ensuring it can be integrated seamlessly into existing substation automation and SCADA systems.

Q: How does the RER670 maintain reliable operation in challenging environmental conditions?

A: Compliant with IEC and EN standards for EMC, shock, vibration, humidity, and wide temperature ranges, the relay is built to withstand harsh operating and storage conditions commonly encountered in power installations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

ENERCON EM 3360 RELAY

ENERCON EM 3360 RELAY

Minimum Order Quantity : 1 Piece

Protect Feature : Other, Shock and Vibration Resistant

Contact Load : Other, 10A at 250V AC

Product Type : Electromechanical Relay

Theory : Other , Electromagnetic Relay

Usage : Electrical Control Panel, Automation Systems

MICOM P442311B2M0360J PROTECTION RELAY

MICOM P442311B2M0360J PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Protect Feature : Other, Overcurrent, Earth Fault, Breaker Failure, Distance Protection

Contact Load : Other, 5A at 250V AC / 30V DC

Product Type : Numerical Protection Relay

Theory : Other , Microcontroller Based Protection

Usage : Feeder, Transformer, and Generator Protection

ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)

ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)

Minimum Order Quantity : 1 Piece

Protect Feature : Other, Transformer differential protection, restricted earth fault, overcurrent, breaker failure

Contact Load : Other, 10A @ 250V AC / 30V DC

Product Type : Protection Relay (Only Display unit)

Theory : Other , Microprocessorbased digital relay

Usage : Protection and control of transformer differential (RET650 series)

SIEMENS 7UM6221-5EB92-3CA0/FF (BF1012106579) GENERATOR PROTECTION RELAY

SIEMENS 7UM6221-5EB92-3CA0/FF (BF1012106579) GENERATOR PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Protect Feature : Other, Comprehensive Generator Protection, Overcurrent, Differential, Earth Fault, Voltage & Frequency Protection

Contact Load : Other, 250 V AC / 8 A (resistive)

Product Type : Generator Protection Relay

Theory : Other , Digital MicroprocessorBased Relay

Usage : Generator Protection



Back to top