ABB RER670 PROTECTION RELAY (ONLY DISPLAY) Specification

  • Coil Power
  • <1.7 W per coil
  • Mechanical Life
  • >10 million operations (per contact relay)
  • Ambient Temperature
  • -25C to +55C (operational)
  • Power Consumption
  • <35 W (typical, depending on setup)
  • Contact Form
  • SPDT or DPDT (configuration dependent)
  • Contact Material
  • AgCdO / AgNi (silver alloy contacts)
  • Dielectiric Strength
  • 2.0 kV RMS, 50 Hz, 1 min
  • Working Temperature
  • -40C to +70C (storage)
  • Coil Voltage
  • 24-250 V DC/AC universal
  • Protect Feature
  • Overcurrent, distance, differential, voltage, frequency protection options
  • Contact Resistance
  • <100 m
  • Product Type
  • Digital Protection Relay Display Unit
  • Insulation Resistance
  • >100 M at 500 V DC
  • Theory
  • Microprocessor based intelligent relay
  • Usage
  • Protection, control and monitoring of power systems
  • Contact Load
  • 8 A at 250 V AC / 30 V DC (resistive load)
  • Operate Time
  • <15 ms (typical depending on function configuration)
  • Terminal Type
  • Screw terminals (plug-in, removable type)
  • Rated Voltage
  • 24-250 V DC/AC (universal auxiliary voltage supply)
  • Supply Terminal
  • Rear and front connection options
  • Size
  • 4U height (19 rack mounting), 1/2 rack width
  • Color
  • Grey/White (Standard ABB relay enclosure)
  • Dimension (L*W*H)
  • W: 177 mm x H: 177 mm x D: 268 mm (typical, excluding connectors)
  • Weight
  • Approx. 6-7 kg (configuration dependent)
  • Data Logging
  • Extended sequence-of-events logging
  • Shock & Vibration
  • IEC 60255-21-1/2/3 compliant
  • Time Synchronization
  • SNTP/NTP & IRIG-B supported
  • Display Type
  • High-resolution graphical LCD, multilingual interface
  • Configuration
  • Flexible, freely programmable logic and settings
  • Protection Class
  • IP 40 (front), IP 20 (rear)
  • EMC Compliance
  • IEC 60255-26, EN 61000-6-2 and 6-4
  • HMI Controls
  • Front panel keypad, push-buttons and navigation keys
  • Mounting
  • Flush, wall or rack mounting options
  • Event Record Storage
  • Multiple fault event and disturbance records
  • Firmware Upgrade
  • Firmware upgradeable via front port or network
  • Relative Humidity
  • 5%-95% (non-condensing)
  • Communication
  • Multiple Ethernet ports, IEC 61850, Modbus, DNP3, 103 protocols supported
 

ABB RER670 PROTECTION RELAY (ONLY DISPLAY) Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ABB RER670 PROTECTION RELAY (ONLY DISPLAY)

ABB RER670 PROTECTION RELAY (ONLY DISPLAY)


ABBs railway application intelligent electronic device (IED), Relion RER670, is used for the protection, control and monitoring of the transmission lines and/or transformers in a two-phase 16.7, 50 and 60 Hz power system design for railway supply. It supports isolated, compensated and solidly earthed networks.



High-Resolution Display and Intuitive HMI

The RER670 relay features a vivid, high-resolution graphical LCD that supports a multilingual interface, making operation and monitoring straightforward for users of varying language backgrounds. The front panel is equipped with a keypad, push-buttons, and navigation keys, enabling efficient local control and fast access to essential settings and event records. This ensures optimal ease-of-use in on-site environments.


Comprehensive Communication Capabilities

Designed to seamlessly integrate into modern power systems, the RER670 supports a wide range of communication protocols including IEC 61850, Modbus, DNP3, and 103, as well as twice Ethernet ports. Flexible network compatibility and robust time synchronization (SNTP/NTP & IRIG-B) facilitate efficient, secure data exchange and grid-wide event coordination. This interoperability is vital for contemporary substations and grid applications.


Configurable and Reliable Protection

With freely programmable logic and settings, the RER670 allows tailored protection strategies, including overcurrent, distance, differential, voltage, and frequency options. Multiple fault event and disturbance records are stored for analysis, and the relay is compliant with high standards for EMC, insulation, shock, and vibration. Designed to operate in a wide temperature range with high mechanical durability, it offers reliability in demanding scenarios.

FAQ's of ABB RER670 PROTECTION RELAY (ONLY DISPLAY):


Q: How can I upgrade the firmware on the ABB RER670 Protection Relay?

A: Firmware can be upgraded on the ABB RER670 via the front communication port or over the network. This flexibility ensures minimal downtime and ensures the latest features and security enhancements are easily deployable.

Q: What are the main benefits of using the high-resolution graphical LCD display?

A: The high-resolution graphical LCD offers clear visibility of system information, supports multiple languages for user convenience, and simplifies navigation through event records, settings, and alarms using the front panel controls.

Q: When should I use the extended event and disturbance recording feature?

A: The extended event and disturbance recording is essential for post-fault analysis and system diagnostics. It captures and stores detailed records of multiple events, helping engineers and operators quickly determine root causes and implement preventive actions.

Q: Where can the ABB RER670 be mounted in a power system setup?

A: This relay offers flexible mounting options, allowing it to be installed flush on panels, attached to walls, or integrated into a standard 19-inch rack, accommodating a variety of substation and control room layouts.

Q: What communication protocols does the RER670 support for system integration?

A: The relay supports multiple protocols, including IEC 61850, Modbus, DNP3, and 103, ensuring it can be integrated seamlessly into existing substation automation and SCADA systems.

Q: How does the RER670 maintain reliable operation in challenging environmental conditions?

A: Compliant with IEC and EN standards for EMC, shock, vibration, humidity, and wide temperature ranges, the relay is built to withstand harsh operating and storage conditions commonly encountered in power installations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

VAMP 57 PROTECTION RELAY

VAMP 57 PROTECTION RELAY

Minimum Order Quantity : 1 Ampere

Size : Other, Approx. 96x96 mm

Color : Grey/Black

Usage : Electrical Protection

Product Type : Protection Relay

C.t.connections For Oc Relay  Adr111a

C.t.connections For Oc Relay Adr111a

Price Range 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Size : Other, Standard module size

Color : Black/White

Usage : Protection and control applications

Product Type : Current Transformer Connection for OC Relay

CONZERV EM 3360 RELAY

CONZERV EM 3360 RELAY

Minimum Order Quantity : 1 Piece

Size : Other, Standard DIN Rail Mount

Color : Light Grey

Usage : Electrical Panels, Energy Metering, Industrial Control Panels

Product Type : Relay Module (Protection Relay)

SIEMENS  7SD6101-5BB99-0BA0EE PROTECTION RELAY

SIEMENS 7SD6101-5BB99-0BA0EE PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Size : Compact, Other

Color : Gray

Usage : Industrial Applications

Product Type : Protection Relay



Back to top