MICOM P442311B2M0360J PROTECTION RELAY
MICOM P442311B2M0360J PROTECTION RELAY
MICOM P442311B2M0360J PROTECTION RELAY
MICOM P442311B2M0360J PROTECTION RELAY
MICOM P442311B2M0360J PROTECTION RELAY
MICOM P442311B2M0360J PROTECTION RELAY
MICOM P442311B2M0360J PROTECTION RELAY
MICOM P442311B2M0360J PROTECTION RELAY

MICOM P442311B2M0360J PROTECTION RELAY

MOQ : 1 Piece

MICOM P442311B2M0360J PROTECTION RELAY Specification

  • Contact Form
  • SPDT / DPDT
  • Protect Feature
  • Overcurrent, Earth Fault, Breaker Failure, Distance Protection
  • Power Consumption
  • < 25 VA
  • Coil Power
  • 1.2 W
  • Dielectiric Strength
  • 2 kV, 50Hz, 1 min
  • Contact Material
  • Silver Alloy
  • Coil Voltage
  • As per Model Configuration
  • Ambient Temperature
  • -10C to +55C
  • Working Temperature
  • -25C to +70C
  • Contact Resistance
  • 100 m
  • Mechanical Life
  • Over 10 million operations
  • Product Type
  • Numerical Protection Relay
  • Insulation Resistance
  • >1000 M at 500 V DC
  • Theory
  • Microcontroller Based Protection
  • Usage
  • Feeder, Transformer, and Generator Protection
  • Contact Load
  • 5A at 250V AC / 30V DC
  • Operate Time
  • Less than 30 ms
  • Terminal Type
  • Screw Type Terminals
  • Rated Voltage
  • 110-250V DC / 100-240V AC
  • Supply Terminal
  • Rear Connection
  • Size
  • Standard 4U Case
  • Color
  • Grey
  • Dimension (L*W*H)
  • 483 x 177 x 240 mm
  • Weight
  • Approx. 4.5 kg
  • Ingress Protection
  • IP40 (Front Panel)
  • Storage Temperature
  • -40C to +85C
  • Protocol Support
  • IEC 61850, Modbus, DNP3
  • Event Recorder
  • Yes, with Time Stamp
  • Mounting Type
  • Panel Mount
  • Frequency
  • 50/60 Hz
  • Display
  • Backlit LCD Display
  • Model Number
  • P442311B2M0360J
  • Number of Inputs/Outputs
  • 8 Digital Inputs, 8 Digital Outputs
  • Communication Ports
  • RS232, RS485, Ethernet Support
 

MICOM P442311B2M0360J PROTECTION RELAY Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About MICOM P442311B2M0360J PROTECTION RELAY

MICOM P442311B2M0360J PROTECTION RELAY


P442311B2M0360J is a numerical distance protection relayfrom the MiCOM Agile P44 series, designed for high and extra-high voltage systems. Key features include:



Comprehensive Protection Features

The MICOM P442311B2M0360J relay delivers essential protection against overcurrent, earth faults, breaker failures, and provides distance protection. Its fast response time, reliable outputs, and event recording capabilities offer assurance for critical electrical infrastructure. Designed for feeder, transformer, and generator protection, this relay ensures operational continuity and system safety.


Flexible Communication and Display

This relay supports versatile connectivity, including RS232, RS485, and Ethernet interfaces. It operates seamlessly with IEC 61850, Modbus, and DNP3 protocols, enabling easy integration with supervisory control systems. The clear backlit LCD display allows users to monitor parameters, review event logs, and configure settings efficiently on-site.


Industrial Durability and Mounting

With an IP40-rated front panel, robust mechanical life exceeding 10 million operations, and high insulation resistance, the MICOM P442311B2M0360J is engineered for endurance. Its panel mount design and rear terminal connections simplify both installation and maintenance in various environments, while the broad temperature range ensures reliable performance in harsh conditions.

FAQ's of MICOM P442311B2M0360J PROTECTION RELAY:


Q: How does the MICOM P442311B2M0360J Protection Relay enhance system reliability?

A: This relay delivers rapid fault detection and isolation with an operate time of less than 30 ms, reducing damage and downtime in electrical networks. Its comprehensive protection features, event recording with time stamps, and robust design collectively enhance operational reliability.

Q: What communication protocols and ports are supported for integration with other devices?

A: The device supports IEC 61850, Modbus, and DNP3 communication protocols and provides RS232, RS485, and Ethernet ports, ensuring compatibility with a variety of supervisory control and automation systems.

Q: When should the relay be used in an electrical system?

A: The relay is ideally suited for protection roles in feeder, transformer, and generator circuits, especially in facilities requiring precise fault monitoring and quick disconnection to prevent equipment damage and outages.

Q: Where is the MICOM P442311B2M0360J typically installed?

A: With its panel-mount design and rear screw-type terminal connections, the relay is commonly installed in control panels or switchgear compartments within substations, power plants, and industrial electrical rooms.

Q: What process should be followed for configuring protection settings?

A: Users can access, monitor, and configure the relay using the backlit LCD display and navigation buttons. Additionally, the relay can be set up using supervisory software through supported communication ports, allowing detailed configuration and monitoring.

Q: How does the event recorder function benefit users?

A: The built-in event recorder stores faults and events with accurate time stamps, enabling engineers to investigate system disturbances, improve diagnostics, and streamline maintenance or troubleshooting routines.

Q: What are the key advantages of its construction and electrical specifications?

A: Its IP40 front panel, high dielectric strength (2 kV for 1 minute), wide ambient and storage temperature tolerance, and durable contacts ensure reliable operation in harsh conditions, extended equipment life, and low maintenance requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

SCHNEIDER CONZERV EM3460 RELAY

SCHNEIDER CONZERV EM3460 RELAY

Minimum Order Quantity : 1 Piece

Usage : Energy monitoring and management

Color : White/Grey

Theory : Other , Electronic Relay

Rated Voltage : 230/415V AC

SIEMENS 7UM6211-5EB92-0AA0/FF (BF1105147780) GENERATOR PROTECTION RELAY

SIEMENS 7UM6211-5EB92-0AA0/FF (BF1105147780) GENERATOR PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Usage : Generator protection applications

Color : Grey/Black front panel

Theory : Other , Microprocessorbased digital protection

Rated Voltage : 24250 V DC / 110230 V AC (auxiliary supply)

ABB REG670AISCWO16I0828 PROTECTION RELAY

ABB REG670AISCWO16I0828 PROTECTION RELAY

Minimum Order Quantity : 1 Ampere

Usage : Protection and control in power systems

Color : Grey

Theory : Other , Microprocessorbased digital relay

Rated Voltage : 110250 V DC, 100240 V AC

CSPC MRI1-I1-R1-S1-R1-HD EARTH FAULT RELAY

CSPC MRI1-I1-R1-S1-R1-HD EARTH FAULT RELAY

Minimum Order Quantity : 1 Piece

Usage : Earth fault protection relay

Color : Black & White Combination

Theory : Other , Earth Leakage/Earth Fault detection by monitoring the residual current

Rated Voltage : 230V AC/110V AC (as per requirement)



Back to top