ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)
ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)
ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)
ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)
ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)
ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)
ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)
ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)

ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)

MOQ : 1 Piece

ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY) Specification

  • Contact Resistance
  • < 50 m
  • Working Temperature
  • -25C to +70C
  • Power Consumption
  • < 50 VA
  • Contact Material
  • Silver Alloy
  • Ambient Temperature
  • -10C to +55C
  • Contact Form
  • SPDT/DPDT (depending on configuration)
  • Protect Feature
  • Transformer differential protection, restricted earth fault, overcurrent, breaker failure
  • Coil Power
  • Not applicable (only display unit)
  • Mechanical Life
  • >10 million operations
  • Coil Voltage
  • Not applicable (only display unit)
  • Dielectiric Strength
  • 2 kV (rms) 1 min between circuits
  • Product Type
  • Protection Relay (Only Display unit)
  • Insulation Resistance
  • > 100 M at 500 VDC
  • Theory
  • Microprocessor-based digital relay
  • Usage
  • Protection and control of transformer differential (RET650 series)
  • Contact Load
  • 10A @ 250V AC / 30V DC
  • Operate Time
  • < 20 ms
  • Terminal Type
  • Screw terminals
  • Rated Voltage
  • 110-230V AC/DC
  • Supply Terminal
  • Rear side terminals
  • Size
  • Big Long (ABB standard format)
  • Color
  • Grey/Black (display front)
  • Dimension (L*W*H)
  • Approx. 483 x 177 x 250 mm
  • Weight
  • Approx. 3.5 kg
  • Disturbance Recorder
  • Integrated, up to 30 seconds
  • Frequency
  • 50/60 Hz
  • Firmware Upgrade
  • Supported via front interface
  • Self Supervision
  • Comprehensive monitoring & diagnostics
  • Model Number
  • RET650 (Only Display Unit)
  • Make
  • ABB
  • Ingress Protection
  • IP40 (front), IP20 (rear)
  • Mounting Type
  • Panel flush mounting
  • Auxiliary Voltage Range
  • 110V - 250V AC/DC
  • Event Recording
  • Up to 1000 events
  • Certification Standards
  • IEC 60255, CE certified
  • Communication Protocols
  • IEC 61850, Modbus, DNP3, IEC 60870-5-103
  • Display Type
  • Big, long, graphical LCD display
 

ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY) Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)

ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)


RET650 offers the best possible coverage for power transformer winding turn-to-turn faults and the unique negative sequence internal/external fault discriminator is faster than a conventional stabilized transformer differential protection function.



Advanced Transformer Protection

Engineered as part of the ABB RET650 series, this protection relay focuses on transformer differential, overcurrent, restricted earth fault, and breaker failure protection. It delivers secure, fast, and precise operational reliability with an operate time of less than 20 ms, making it ideal for vital power system applications.


Modern Connectivity and Easy Upgrades

Supporting a range of communication protocols-IEC 61850, Modbus, DNP3, and IEC 60870-5-103-the RET650 ensures smooth integration into SCADA and substation automation systems. Firmware upgrades are hassle-free through the front interface, minimizing system downtime during updates.


Comprehensive Monitoring and Recording

Equipped with integrated event recording (up to 1000 events) and a disturbance recorder (up to 30 seconds), operators have access to crucial post-fault analysis. Its comprehensive self-supervision and diagnostics further enhance operational security, identifying and communicating issues promptly.

FAQ's of ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY):


Q: How can firmware be upgraded on the ABB RET650 BIG LONG PROTECTION RELAY (ONLY DISPLAY)?

A: Firmware upgrades are supported via the device's front interface. This allows users to conveniently update the relay without needing to remove it from service, ensuring minimal operational disruption and keeping the unit up to date with the latest features.

Q: What are the main protection features provided by the RET650 display unit?

A: The RET650 (Only Display Unit) offers transformer differential protection, restricted earth fault protection, overcurrent protection, and breaker failure protection, making it highly suitable for transformer safety and coordinated control in electrical substations.

Q: When is event and disturbance data recorded by the relay?

A: The relay can record up to 1000 events and capture disturbance records for up to 30 seconds during abnormal or fault events. This data facilitates detailed analysis of incidents and aids in root cause investigation after system events.

Q: Where should the ABB RET650 (Only Display Unit) be installed for optimal performance?

A: Designed for panel flush mounting, the unit should be installed in a dry, protected control room or substation panel with ambient temperatures between -10C and +55C, ensuring both operational reliability and compliance with IP40/IP20 protection ratings.

Q: What are the benefits of using the RET650's big, long graphical LCD display?

A: The expansive graphical LCD display provides a clear, intuitive user interface for real-time monitoring, relay settings configuration, and diagnostics. This leads to faster decision-making and easier maintenance for operators.

Q: How does the relay integrate with different substation communication systems?

A: With support for IEC 61850, Modbus, DNP3, and IEC 60870-5-103, the RET650 can seamlessly interface with a wide variety of SCADA and automation systems, enhancing operational flexibility and data visibility across energy networks.

Q: What certifications and safety standards does the RET650 (Only Display Unit) comply with?

A: The RET650 meets IEC 60255 standards, carries CE certification, and offers robust insulation and dielectric strength. Its IP40 (front)/IP20 (rear) ingress protection rating ensures durability and safety in professional environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

SIEMENS 7UM6221-6EB92-0CB0FF PROTECTION RELAY

SIEMENS 7UM6221-6EB92-0CB0FF PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Working Temperature : Placeholder

Power Consumption : Placeholder

Weight : Placeholder

Theory : Placeholder, Other

ABB REX521EHHPSH02E RELAY

ABB REX521EHHPSH02E RELAY

Minimum Order Quantity : 1 Piece

Working Temperature : 10C to +55C

Power Consumption : <20 VA

Weight : Approx. 3.5 kg

Theory : Other , Digital / Microprocessor Based Relay

CONZERV EM 3480 RELAY

CONZERV EM 3480 RELAY

Minimum Order Quantity : 1 Piece

Working Temperature : 10C to +55C

Power Consumption : < 2.2 VA

Weight : Approx 230g

Theory : Other , Electromagnetic Relay

SIEMENS 7UM6221-5EB92-3CA0/FF (BF1012106585) GENERATOR PROTECTION RELAY

SIEMENS 7UM6221-5EB92-3CA0/FF (BF1012106585) GENERATOR PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Working Temperature : 20C to +60C

Power Consumption : < 20 W

Weight : Approx. 7 kg

Theory : Other , Microprocessor Based Protection



Back to top