ZOTUP SPD L 25-100 230 t ff 3+1 PLC
ZOTUP SPD L 25-100 230 t ff 3+1 PLC
ZOTUP SPD L 25-100 230 t ff 3+1 PLC
ZOTUP SPD L 25-100 230 t ff 3+1 PLC
ZOTUP SPD L 25-100 230 t ff 3+1 PLC
ZOTUP SPD L 25-100 230 t ff 3+1 PLC
ZOTUP SPD L 25-100 230 t ff 3+1 PLC
ZOTUP SPD L 25-100 230 t ff 3+1 PLC

ZOTUP SPD L 25-100 230 t ff 3+1 PLC

MOQ : 1 Piece

ZOTUP SPD L 25-100 230 t ff 3+1 PLC Specification

  • Application
  • Protection against lightning and surge for PLCs and power supply
  • Phase
  • 3+1 (TNS/TNC systems)
  • Load Capacity
  • Maximum continuous operating voltage (Uc): 255 V AC
  • Remote Control
  • Yes
  • Cable Length
  • Not included
  • Weight
  • Approx. 400 g
  • Mounting Type
  • 35 mm DIN rail
  • Features
  • Replaceable module, pluggable with visual fault indicator
  • Frequency
  • 50/60 Hz
  • Automation Grade
  • Automatic
  • Connectivity Type
  • DIN rail terminal
  • Control Type
  • Surge protection (non-manual)
  • IP Rating
  • IP20
  • Material
  • Thermoplastic housing, Metal terminal parts
  • Power
  • 25 kA (8/20 s) per pole
  • Temperature
  • -40C to +80C
  • Voltage
  • 230 V AC
  • Connection
  • Multi-stranded or rigid copper wires, 1.5-35 mm2
  • Standards Compliance
  • EN 61643-11, IEC 61643-11
  • Fault Indication
  • Optical indicator on device
  • Short-Circuit Withstand
  • Up to 50 kArms (with backup fuse)
  • Rating Category
  • SPD for power supply lines and PLC systems
  • Response Time
  • < 25 ns
  • Maximum Discharge Current (Imax)
  • 100 kA (8/20 s) per pole
  • Protection Mode
  • Type 1+2 (Class I + II)
  • Nominal Discharge Current (In)
  • 25 kA (8/20 s)
  • Model
  • L 25-100 230 t ff 3+1 PLC
  • Replacement Module Code
  • RM-L25-100-230-PLC
 

ZOTUP SPD L 25-100 230 t ff 3+1 PLC Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ZOTUP SPD L 25-100 230 t ff 3+1 PLC

ZOTUP SPD L 25-100 230 t ff 3+1 PLC


L 25/100 230 t ff 3+1 is a ready to install assembly of three voltage limiting and a voltage switching SPD providing ten modes of protection, typically installed in three-phase plus neutral 230/400 V TT-systems where connection type CT2 (3+1) is required according to HD 60364-5-534, e.g. in the Main Distribution Board (MDB).

  • Impulse test classification: Test class I and II according to IEC 61643-11 Ed. 1 (2011-03) and Type 1 and 2 according to EN 61643-11 (2012-10);
  • Backup protection is not required with an upstream CB 160 A or up to an Isccr 5 kA rms;
  • Three colour Status Indicator with progressive indication of remaining performance.

 



Advanced Surge Protection for PLC Systems

The ZOTUP SPD L 25-100 230 t ff 3+1 PLC is designed to provide outstanding protection to sensitive automation and power infrastructure. With a rapid response time below 25 ns and the ability to withstand up to 50 kArms with a backup fuse, this device ensures system reliability even in extreme conditions. Compatibility with Indian industrial standards assures both safety and resilience.


Easy Maintenance with Replaceable Modules

Equipped with pluggable replacement modules (RM-L25-100-230-PLC) and a visible optical fault indicator, the ZOTUP SPD streamlines maintenance. This feature allows for quick swaps of faulty modules without system downtime, reducing operational interruptions and maintenance costs.

FAQ's of ZOTUP SPD L 25-100 230 t ff 3+1 PLC:


Q: How do I install the ZOTUP SPD L 25-100 230 t ff 3+1 PLC in my electrical system?

A: Installation is straightforward; mount the device on a standard 35 mm DIN rail and connect it using multi-stranded or rigid copper wires (1.5-35 mm2). Ensure connections align with the phase configuration (3+1 for TNS/TNC systems), and follow all relevant safety standards during setup.

Q: What are the main benefits of using this SPD for PLC and power supply protection?

A: The main benefits include high surge handling up to 100 kA per pole, rapid response time (<25 ns), a pluggable replaceable module for minimal downtime, and an optical indicator for immediate fault identification. These features minimize the risk of equipment damage and ensure reliable operation.

Q: When should the replacement module (RM-L25-100-230-PLC) be used?

A: Replace the module when the optical fault indicator shows a fault. This visual cue helps identify compromised protection and supports timely maintenance without full device replacement.

Q: Where can this SPD be used effectively?

A: This SPD is ideal for power supply lines and PLC systems, especially in environments prone to lightning strikes or electrical surges. Its robust construction and type 1+2 classification make it suitable for industries, commercial facilities, and distributed control systems.

Q: What process should I follow for maintenance and checking the device's condition?

A: Regularly inspect the optical indicator for any fault signals. If a fault is shown, use the appropriate replacement module to swap out the damaged unit. Always ensure power is isolated during maintenance, and adhere to relevant electrical safety protocols.

Q: How does the device comply with international safety standards?

A: The ZOTUP SPD L 25-100 230 t ff 3+1 PLC meets EN 61643-11 and IEC 61643-11 standards, ensuring it provides reliable protection and performance in accordance with international requirements for surge protective devices.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Industrial Automation Category

KEB 00.F4.010-7009 BUS OPERATOR RS 485

KEB 00.F4.010-7009 BUS OPERATOR RS 485

Minimum Order Quantity : 1 Piece

Features : Plugandplay, industrial reliability, compact design, multidevice support

Connectivity Type : Bus Operator RS 485

Material : Highquality industrial plastic

Application : Fieldbus communication, industrial automation, KEB drives

Mounting Type : DIN rail mounting

SINRO SRD02-08230FK2 VARIABLE AIR DAMPER MOTOR

SINRO SRD02-08230FK2 VARIABLE AIR DAMPER MOTOR

Minimum Order Quantity : 1 Piece

Features : Fail Safe Spring Return, Manual Override

Connectivity Type : Wired

Material : Aluminum Alloy

Application : HVAC Air Damper Control

Mounting Type : Direct Mount

LEADSHINE L5-400

LEADSHINE L5-400

Features : High Precision Compact Design

Connectivity Type : Wired

Material : Aluminum

Application : Industrial Automation

Mounting Type : Horizontal

TAIYO DS-21-2F AUTOMATIC VOLTAGE REGULATOR

TAIYO DS-21-2F AUTOMATIC VOLTAGE REGULATOR

Minimum Order Quantity : 5 Pieces

Features : Overload Protection, Short Circuit Protection, High & Low Voltage Cutoff

Connectivity Type : Wired

Material : Metal Body with Copper Winding

Application : Industrial, Commercial, Home Appliances

Mounting Type : Wall Mount/Surface Mount



Back to top