SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY
SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY
SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY
SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY
SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY
SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY

SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY

MOQ : 1 Piece

SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY Specification

  • Contact Form
  • 2 changeover (SPDT) contacts
  • Mechanical Life
  • >10 million operations (relay contacts)
  • Protect Feature
  • Line differential, Overcurrent, Distance, Backup protection
  • Dielectiric Strength
  • 2 kV, 50 Hz, 1 min
  • Working Temperature
  • -10C to +55C
  • Ambient Temperature
  • -25C to +70C
  • Coil Voltage
  • Integrated electronics, not applicable
  • Contact Material
  • Silver alloy
  • Power Consumption
  • Max. 18 W
  • Contact Resistance
  • 50 m
  • Product Type
  • Numerical Protection Relay
  • Insulation Resistance
  • >100 M at 500 V DC
  • Theory
  • Microprocessor-based protection
  • Usage
  • Feeder protection, Distance protection, Line differential protection
  • Contact Load
  • 5 A at 250 V AC, 0.2 A at 110 V DC
  • Operate Time
  • Typically 20 ms
  • Terminal Type
  • Plug-in type
  • Rated Voltage
  • 24-250 V DC, 110-230 V AC/DC
  • Supply Terminal
  • Rear connection terminals
  • Size
  • 19 rack, 4U height
  • Color
  • Grey
  • Dimension (L*W*H)
  • Approximately 173 x 483 x 245 mm
  • Weight
  • Approx. 4.3 kg
  • Protection Class
  • IP54 front, IP20 rear (per EN 60529)
  • Binary Inputs/Outputs
  • 16 binary inputs, 14 output relays
  • Display Language
  • Multilingual support
  • Standards Compliance
  • IEC 60255, EN 60255, DIN VDE 0435, IEC 61850
  • Mounting Method
  • Flush mounting (19-inch rack) or panel mounting
  • Display Type
  • Backlit LCD with function keys
  • Time Synchronization
  • SNTP/NTP, IRIG-B
  • Communication Interfaces
  • FO/RS485/RS232, IEC 60870-5-103, IEC 61850, Profibus, Ethernet
  • User Manual
  • Supplied with device
  • Firmware Upgrade
  • Software upgradable via communication port
  • Fault Locator
  • Integrated, event and fault recording features
  • Typical Applications
  • HV, EHV and MV lines, utility substations, industrial substations
  • CT/PT Inputs
  • 8 CT and 4 VT inputs
  • Event/Disturbance Recorder
  • Yes, integrated
 

SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY

SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY


SIEMENS SIPROTEC 7SD6101-5BB99-0BA0/EE LINE DIFFERENTIAL PROTECTON RELAY

SIEMENS

SIPROTEC 7SD61

7SD6101-5BB99-0BA0/EE

LINE DIFFERENTIAL PROTECTON RELAY

F.-NR.: BF1408516766 L0R+M2G

In = 1A,50-60Hz

Un = 100...125V AC

IL = 5A/240V AC

Uh = 110...250V DC

115...230V AC

DIAGR.: C53000-B1174-C145-*

OPERATION ONLY WITH FIXED COVER

SWITING LOAD OF OUTPUT TRIP REALYS

120V AC PILOT DUTY,B300

240V AC PILOT DUTY,B300

240V AC 5A GENERAL PURPOSE

24V DC 5A GENERAL PURPOSE

48V DC 0.8A GENERAL PURPOSE

240V DC 0.1A GENERAL PURPOSE

120V AC 1/6Hp (4.4 FLA)

240V AC 1/2Hp (4.9 FLA)

SWITCHING LOAD OF DC MOTOR RELAYS IF EXIT

240V DC 1.6 FLA

120V DC 3.2 FLA

60V DC 5.5 FLA

69CA

Tsurr : MAX.70'C NORMAL OP.



Comprehensive Protection and Monitoring

This relay combines line differential, distance, and overcurrent protection with seamlessly integrated fault location and disturbance recording features, making it ideal for demanding high- and medium-voltage environments. Its microprocessor-based design guarantees precision operation and rapid, dependable protection in critical infrastructure.


Flexible Communication and Integration

Equipped with FO/RS485/RS232, IEC 60870-5-103, IEC 61850, Profibus, and Ethernet interfaces, the relay supports modern automation systems. Firmware upgrades are enabled via communication ports, allowing adaptability for evolving network requirements.


User-Friendly Operation and Installation

The SIEMENS relay features a backlit LCD display with function keys for intuitive configuration and monitoring. It is suitable for flush or panel mounting in 19-inch racks, includes plug-in connection terminals, and supports multilingual displays, ensuring straightforward commissioning and versatile application.

FAQ's of SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY:


Q: How is the SIEMENS 7SD6101-5BB99-0BA0/EE protection relay typically used in substations?

A: This relay is primarily used for protecting HV, EHV, and MV lines in utility and industrial substations. It provides line differential, distance, and overcurrent protection to ensure equipment and personnel safety, while integrated fault location and event recording streamline maintenance and diagnostics.

Q: What communication interfaces are available, and what benefits do they offer?

A: The device includes FO/RS485/RS232, IEC 60870-5-103, IEC 61850, Profibus, and Ethernet interfaces. These allow seamless integration into modern substation automation systems and remote monitoring, facilitating interoperability and enhancing system responsiveness.

Q: Where should the relay be installed, and what are the mounting options?

A: The SIEMENS relay can be installed in a 19-inch rack using flush mounting or directly onto a panel. Rear plug-in terminals simplify cable management while ensuring reliable connections for both new and retrofit installations.

Q: How can firmware upgrades be performed on this protection relay?

A: Firmware upgrades are performed via the relay's communication ports using the supplied software tools. This process ensures devices stay up-to-date with the latest features and security enhancements without physical replacement.

Q: What benefits does the integrated event and disturbance recorder provide?

A: The built-in event and fault recorder automatically logs disturbances and operational data. This feature greatly assists maintenance teams in fault analysis, cause identification, and system recovery, enhancing reliability and reducing downtime.

Q: When is time synchronization necessary, and how is it achieved with this relay?

A: Accurate time synchronization is crucial for precise recording and coordination across protection devices. The relay supports SNTP/NTP and IRIG-B protocols, ensuring all logged events are timestamped consistently for post-event analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

ABB REG670AISCWO16I0828 PROTECTION RELAY

ABB REG670AISCWO16I0828 PROTECTION RELAY

Minimum Order Quantity : 1 Ampere

Weight : Approx. 6 kg

Power Consumption : Max. 60 VA

Contact Resistance : <100 m

Insulation Resistance : >100 M @ 500 V DC

Coil Voltage : Not applicable (solidstate relay)

ABB RER670 PROTECTION RELAY (ONLY DISPLAY)

ABB RER670 PROTECTION RELAY (ONLY DISPLAY)

Minimum Order Quantity : 1 Piece

Weight : Approx. 67 kg (configuration dependent)

Power Consumption : <35 W (typical, depending on setup)

Contact Resistance : <100 m

Insulation Resistance : >100 M at 500 V DC

Coil Voltage : 24250 V DC/AC universal

MICOM P442311B2M0360J PROTECTION RELAY

MICOM P442311B2M0360J PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Weight : Approx. 4.5 kg

Power Consumption : < 25 VA

Contact Resistance : 100 m

Insulation Resistance : >1000 M at 500 V DC

Coil Voltage : As per Model Configuration

ALLEN BRADLEY MSR132EP SAFETY RELAY

ALLEN BRADLEY MSR132EP SAFETY RELAY

Minimum Order Quantity : 1 Piece

Weight : 250g

Power Consumption : < 3 W

Contact Resistance : < 100 m

Insulation Resistance : > 100 M

Coil Voltage : 24V DC



Back to top