Over Current Earth Fault Relay  03118738
Over Current Earth Fault Relay  03118738
Over Current Earth Fault Relay  03118738
Over Current Earth Fault Relay  03118738

Over Current Earth Fault Relay 03118738

MOQ : 1 Piece

Over Current Earth Fault Relay 03118738 Specification

  • Contact Form
  • SPDT
  • Dielectiric Strength
  • 2,000V AC for 1 minute
  • Mechanical Life
  • 10,000 operations
  • Contact Material
  • Silver alloy
  • Coil Power
  • 2-5VA
  • Coil Voltage
  • 110V/220V AC
  • Contact Resistance
  • <50 m
  • Working Temperature
  • -10C to +55C
  • Power Consumption
  • <5VA
  • Protect Feature
  • Over current and earth fault protection
  • Ambient Temperature
  • -10C to +55C
  • Product Type
  • Over Current Earth Fault Relay
  • Insulation Resistance
  • > 100 M at 500V DC
  • Theory
  • Electromagnetic Relay
  • Usage
  • Protection against over current and earth fault in electrical circuits
  • Contact Load
  • 5A at 250V AC
  • Operate Time
  • <30 ms
  • Terminal Type
  • Screw terminals
  • Rated Voltage
  • 110V/220V AC
  • Supply Terminal
  • Single phase/Three phase
  • Size
  • Standard panel mounting
  • Color
  • Black
  • Dimension (L*W*H)
  • 96mm x 96mm x 110mm
  • Weight
  • Approx. 400 g
  • IP Rating
  • IP30
  • Reset
  • Manual/Automatic
  • LED Indication
  • Trip and operation indication
  • Response Time
  • Fast response
  • Mounting Type
  • Flush/Panel Mount
  • Relay Type
  • Electromechanical
  • Trip Setting Range
  • Adjustable
  • Housing Material
  • Flame retardant ABS plastic
  • Frequency
  • 50/60 Hz
 

Over Current Earth Fault Relay 03118738 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Over Current Earth Fault Relay 03118738



Discover the latest Over Current Earth Fault Relay 03118738, a crowning champion in circuit protection. With robust electromechanical technology, this majestic device offers top-tier protection against over current and earth faults. Adjustable trip settings and rapid response time (<30 ms) ensure reliable operation. Its flush/panel mount design, reduced power consumption, and flame-retardant ABS housing set it apart. Complete with manual/automatic reset, LED indications, and screw terminals, this relay is a preferred choice for distributors, importers, and service providers seeking enhanced safety across electrical circuits.

Versatile Applications and Usage Method

The Over Current Earth Fault Relay 03118738 is widely utilized across industrial, commercial, and utility sectors, championing protection in distribution panels, generators, and transformer circuits. Its flush/panel mount facilitates quick installation, while its use type accommodates both single-phase and three-phase systems. Set using an adjustable range, this relay seamlessly integrates for proactive protection against faults in various electrical applications, establishing itself as an essential safety measure for reliable network operations.


Certifications, Export Markets, and Shipping

Esteemed for its adherence to rigorous industry standards, the Over Current Earth Fault Relay 03118738 is regularly shipped by trusted transport services to key global markets, with a list price reflecting competitive supply ability. Main export destinations include Asia, Africa, and the Middle East, facilitating steady demand. Our strong distribution network ensures prompt delivery and reliable aftersales support, reinforcing commitment to safety, quality assurance, and customer satisfaction worldwide.


FAQs of Over Current Earth Fault Relay 03118738:


Q: How does the Over Current Earth Fault Relay 03118738 operate?

A: The relay operates using electromechanical principles to detect over current and earth faults in electrical circuits. Upon detection, it triggers a trip response in less than 30 milliseconds and displays operation or fault using LED indicators.

Q: What are the primary applications of this relay?

A: This relay is mainly used in electrical distribution panels, generator protection, and transformer circuits across industrial, commercial, and utility infrastructures to safeguard against over current and earth faults.

Q: When should the relays trip settings be adjusted?

A: Adjustment should be carried out during installation or system configuration to align with the specific protection requirements of your electrical network, ensuring optimal safety and equipment longevity.

Q: Where can this relay be installed?

A: The relay is designed for flush or panel mounting, suitable for standard panel spaces in control rooms, switchgear cabinets, and electrical enclosures for single-phase or three-phase circuit protection.

Q: What is the benefit of having manual and automatic reset features?

A: Manual and automatic reset options allow flexibility: manual ensures the fault has been cleared safely before restarting, while automatic reset enables prompt return to service after transient faults, reducing downtime.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

ENERCON EM 3360 RELAY

ENERCON EM 3360 RELAY

Minimum Order Quantity : 1 Piece

Color : Black & Grey

Product Type : Electromechanical Relay

Usage : Electrical Control Panel, Automation Systems

Contact Load : Other, 10A at 250V AC

ABB RET650 Transformer protection RELAY

ABB RET650 Transformer protection RELAY

Minimum Order Quantity : 1 Piece

Color : Grey

Product Type : Transformer Protection Relay

Usage : Transformer Protection

Contact Load : Other, 5 A at 250 V AC or 30 V DC

WAGO 750-512 RELAY

WAGO 750-512 RELAY

Minimum Order Quantity : 1 Piece

Color : Gray

Product Type : Digital Output Relay Module

Usage : Relay module for fieldbus systems

Contact Load : Other, 250 V AC / 30 V DC, 2 A

C&S IRIPRO-V3-3I-EI-V-H-1-1 CURRENT PROTCTION RELAYS

C&S IRIPRO-V3-3I-EI-V-H-1-1 CURRENT PROTCTION RELAYS

Minimum Order Quantity : 1 Piece

Color : Grey

Product Type : Digital current protection relay

Usage : Current protection in electrical panels

Contact Load : Other, 5A at 250V AC



Back to top