About MITSUBISHI A1SJ71E71-B2-S3 PLC
MITSUBISHI A1SJ71E71-B2-S3 PLC
The Mitsubishi A1SJ71E71-B2-S3 is an advanced Ethernet communication module designed to enable efficient data transfer and dependable network integration. This module plays a critical role in the operation of intricate systems that necessitate reliable and accurate communication protocols. One notable characteristic of the A1SJ71E71-B2-S3 is its inclusion of a 512KB SRAM memory card, which provides ample capacity for storing data and facilitates efficient data processing operations. The module is specifically engineered to be compatible with a 10BASE2 network, offering the capability for rapid data transmission and thereby facilitating efficient and seamless communication within the system. The A1SJ71E71-B2-S3 is notable for its data conversion functionalities. The module demonstrates a conversion rate of 100 milliseconds per 16 channels, facilitating fast data processing and improving the overall performance of the system. The system is capable of accommodating 16 analog channels, each with an input/output resolution range of 0 to 4000. This feature guarantees the execution of precise and accurate data input and output operations. The module features 32 output points, offering a substantial quantity of connection interfaces to accommodate a wide variety of systems. Additionally, it sustains a minimal OFF leakage current of 0.1 mA, which enhances energy efficiency and ensures reliable operation. The A1SJ71E71-B2-S3 is designed to efficiently balance power input and output. It accepts an input voltage range of 100240 volts AC and delivers a rated output of 5 Volts DC at 3 Amps and 24 Volts DC at 0.6 Amps. The module has dimensions of 2.0 inches by 6.0 inches by 4.0 inches and weighs 0.2 kilograms. It is engineered to have a small size and low weight, which facilitates convenient installation and integration into systems.
Expand Communication in AutomationThe A1SJ71E71-B2-S3 enables seamless Ethernet communication for Mitsubishi MELSEC PLCs, allowing integration into modern industrial networks. Its robust design with IP20-rated housing ensures durability and stable operation even in demanding environments. Fast data transmission at 10Mbps supports enhanced process monitoring and remote control functions.
Versatile Mounting and Easy IntegrationThis module supports convenient DIN rail or panel mounting, offering flexibility during installation. With Ethernet RJ45 connectors and LED status lights, it simplifies connection and monitoring. The expansion module is powered directly by the PLC base unit, making it straightforward to integrate into existing systems without additional power supplies.
FAQs of MITSUBISHI A1SJ71E71-B2-S3 PLC:
Q: How do I install the A1SJ71E71-B2-S3 Ethernet module to my Mitsubishi MELSEC PLC system?
A: To install, simply slot the module into the expansion slot on your MELSEC PLC base unit. Wiring is done via the RJ45 Ethernet connector. Follow the user manual for correct DIN rail or panel mounting and ensure power is supplied from the base unit at 5 V DC.
Q: What types of industrial applications is this module suitable for?
A: This module is ideal for industrial automation tasks such as remote I/O, process monitoring, and factory automation. Its reliable Ethernet connectivity and fast data transmission make it optimal for applications requiring real-time communication and centralized control.
Q: When should I use this communication module instead of a standard module?
A: Use the A1SJ71E71-B2-S3 when you need Ethernet-based networking, remote control, or integration with other networked systems. It is particularly beneficial in environments demanding high-speed and reliable data exchange between multiple devices.
Q: Where can the A1SJ71E71-B2-S3 module be mounted in an automation setup?
A: This expansion module can be DIN rail or panel mounted inside an electrical cabinet or control panel, following standard industrial installation practices. Ensure the surrounding temperature is within 0C to 55C during operation for optimal performance.
Q: What is the process for configuring Ethernet communications using this module?
A: After installation, configure the communication settings using the MELSEC protocol in your programming software. Connect the Ethernet cable between the modules RJ45 port and your network, then set up IP addresses and link to remote devices as per your system architecture.
Q: How does the module benefit an industrial automation system?
A: It enhances system efficiency by enabling high-speed, reliable Ethernet communications, thereby supporting remote monitoring, centralized data collection, and flexible integration with other factory systems. This leads to improved responsiveness and streamlined process control.
Q: What is the maximum cable length supported for data communication?
A: The module follows Ethernet standards, supporting cable lengths up to 100 meters (using category-compliant cables), facilitating flexible installation across large industrial facilities.