EASUN MIT 161 PROTECTION HEALTHY RELAY
EASUN MIT 161 PROTECTION HEALTHY RELAY
EASUN MIT 161 PROTECTION HEALTHY RELAY
EASUN MIT 161 PROTECTION HEALTHY RELAY
EASUN MIT 161 PROTECTION HEALTHY RELAY
EASUN MIT 161 PROTECTION HEALTHY RELAY
EASUN MIT 161 PROTECTION HEALTHY RELAY
EASUN MIT 161 PROTECTION HEALTHY RELAY

EASUN MIT 161 PROTECTION HEALTHY RELAY

MOQ : 1 Piece

EASUN MIT 161 PROTECTION HEALTHY RELAY Specification

  • Contact Form
  • 1 C/O (SPDT)
  • Coil Voltage
  • Powered by Rated Voltage Input
  • Power Consumption
  • < 3VA
  • Contact Material
  • Silver Alloy
  • Dielectiric Strength
  • 2,000V AC for 1 min
  • Protect Feature
  • Over/Under Voltage & Phase Failure/Sequence protection
  • Mechanical Life
  • 10,000,000 operations (min.)
  • Coil Power
  • Direct Supply Driven
  • Ambient Temperature
  • -10C to +55C
  • Working Temperature
  • -10C to +55C
  • Contact Resistance
  • < 100 m
  • Product Type
  • Protection Healthy Relay
  • Insulation Resistance
  • > 100 M at 500V DC
  • Theory
  • Electromagnetic Relay
  • Usage
  • Protection and monitoring of healthy status in electrical circuits
  • Contact Load
  • 5A at 250V AC/30V DC (Resistive)
  • Operate Time
  • 100 ms typ.
  • Terminal Type
  • Screw terminals
  • Rated Voltage
  • 110-240V AC/DC
  • Supply Terminal
  • Front terminal blocks
  • Size
  • Standard DIN 35 mm Mount
  • Color
  • Grey
  • Dimension (L*W*H)
  • Approx. 96 x 22.5 x 75 mm
  • Weight
  • Approx. 180 g
  • Response Time
  • < 100 ms
  • Enclosure Protection
  • IP20
  • Indicator
  • LED for relay status
  • Relative Humidity
  • Up to 95% RH (Non-condensing)
  • Application Area
  • Power Panels, MCCs, Distribution Boards
  • Reset Method
  • Automatic/Manual
  • Frequency
  • 50/60 Hz
  • Storage Temperature
  • -25C to +70C
  • Mounting Type
  • DIN Rail Mount
 

EASUN MIT 161 PROTECTION HEALTHY RELAY Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About EASUN MIT 161 PROTECTION HEALTHY RELAY

EASUN MIT 161 PROTECTION HEALTHY RELAY


The type MIT161 numerical sensitive current protection relay combines the power and flexibility of microprocessor technology. The relay is especially tuned to suit applications where low settings, low burden and rejection of harmonic currents become a necessity.




Comprehensive Electrical Protection

The EASUN MIT 161 relay provides precise protection against over and under voltage, phase failure, and phase sequence faults. Designed to ensure safety and operational reliability in critical electrical environments, this device helps prevent electrical hazards and equipment damage. Its suitability for MCCs, distribution boards, and power panels enhances the safeguarding of key infrastructure.


Reliable, Fast, and Durable Operation

Featuring a rapid response time (< 100 ms) and both automatic and manual reset methods, the EASUN MIT 161 adapts easily to varied operational needs. The relay supports a high contact load and is engineered for longevity, with a mechanical life of over 10 million operations. Its robust build, IP20 protection, and silver alloy contacts guarantee dependable service even under demanding conditions.


User-Friendly Installation and Monitoring

Designed for hassle-free installation, the relay comes with screw terminals and front terminal blocks. The LED indicator provides instant visual status updates for relay operation, making monitoring straightforward. With its standard DIN 35 mm mount and compact dimensions, the EASUN MIT 161 fits seamlessly into a variety of electrical panels, ensuring flexibility and ease of use.

FAQ's of EASUN MIT 161 PROTECTION HEALTHY RELAY:


Q: How is the EASUN MIT 161 relay installed?

A: The EASUN MIT 161 relay is designed for DIN rail mounting, making it quick and convenient to install in power panels, motor control centers (MCCs), and distribution boards using standard 35 mm DIN rails.

Q: What protection features does this relay offer for electrical circuits?

A: The relay provides robust protection against over and under voltage, phase failure, and incorrect phase sequence. These features help maintain the healthy status of electrical systems and prevent potential damage or hazards.

Q: When should I use the automatic versus manual reset method?

A: Choose the automatic reset for applications where minimal downtime is desired after a fault is cleared. Use the manual reset in systems that require operator supervision to ensure safety or when local troubleshooting is needed.

Q: Where is the EASUN MIT 161 most commonly used?

A: This relay is commonly utilized in power panels, MCCs, and distribution boards within industrial, commercial, and utility setups, especially where reliable monitoring and protection of electrical circuits are essential.

Q: What process should I follow to monitor the relay status?

A: You can monitor the relay's operational status through its LED indicator, which provides immediate, clear information about the relay's condition, facilitating quick diagnostics and system checks.

Q: How does the EASUN MIT 161 ensure reliable operation in harsh environments?

A: With a wide operating temperature range (-10C to +55C), high humidity tolerance (up to 95% RH non-condensing), and robust IP20 enclosure, the relay is built to perform consistently even in challenging environments.

Q: What are the key benefits of using the EASUN MIT 161 relay?

A: Key benefits include its fast response time, long mechanical life, easy installation, comprehensive protection features, straightforward monitoring with LED indication, and adaptability to various voltages (110-240V AC/DC).

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

SIEMENS 7UM6221-6EB92-0CB0FF PROTECTION RELAY

SIEMENS 7UM6221-6EB92-0CB0FF PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Theory : Placeholder, Other

Terminal Type : Other, Placeholder

Color : Gray

Protect Feature : Other, Overcurrent and fault protection

SIEMENS 7SD5221-5AB29-0CK0/GG (DISPLAY DAMAGE) MULTI TERMINAL LINE PROTECTION

SIEMENS 7SD5221-5AB29-0CK0/GG (DISPLAY DAMAGE) MULTI TERMINAL LINE PROTECTION

Minimum Order Quantity : 1 Piece

Theory : Other , Numerical Differential Protection

Terminal Type : Other, Screwtype Terminals

Color : Grey

Protect Feature : Other, Line Differential, Distance, Earth Fault & Pilot Protection

ABB REF615E E HBFCACABNCA1BNN1XE RELAY

ABB REF615E E HBFCACABNCA1BNN1XE RELAY

Minimum Order Quantity : 1 Piece

Theory : Other , Electromechanical/Intelligent Digital Processing

Terminal Type : Other, Screw

Color : Silver/White

Protect Feature : Other, Overcurrent Earth Fault Voltage Frequency protection

VAMP 50 PROTECTION RELAY

VAMP 50 PROTECTION RELAY

Minimum Order Quantity : 1 Ampere

Theory : Other , Digital Protection Relay

Terminal Type : Other, Push Button Controls

Color : Beige and Green

Protect Feature : Overcurrent Earth Fault, Other



Back to top