Icc211 For current output icc211-i1-01 Specification

  • Dielectiric Strength
  • 2,000V AC/minute
  • Contact Resistance
  • 100 m
  • Coil Voltage
  • 24V DC
  • Coil Power
  • 0.9W
  • Contact Material
  • Silver Alloy
  • Ambient Temperature
  • -20C to +55C
  • Protect Feature
  • Overload Protection
  • Mechanical Life
  • 10,000,000 times
  • Working Temperature
  • -10C to +40C
  • Power Consumption
  • < 0.9W
  • Contact Form
  • SPDT (1c)
  • Product Type
  • Current Output Relay Module
  • Insulation Resistance
  • > 100 M (at 500V DC)
  • Theory
  • Electromagnetic Relay
  • Usage
  • Current Output Monitoring
  • Contact Load
  • 10A 250VAC/24VDC
  • Operate Time
  • 15 ms
  • Terminal Type
  • Screw type
  • Rated Voltage
  • AC 250V
  • Supply Terminal
  • 2 terminals
  • Size
  • Standard industrial module size
  • Color
  • Black and White
  • Dimension (L*W*H)
  • 90 mm 22.5 mm 70 mm
  • Weight
  • Approximately 110g
  • Input Signal
  • Current or voltage depending on configuration
  • Mounting Type
  • DIN Rail
  • Storage Temperature
  • -25C to +70C
  • Response Time
  • < 30 ms
  • Output Current Range
  • 4-20mA
  • Housing Material
  • Flame retardant ABS
  • Frequency
  • 50/60Hz
  • LED Indicator
  • Power and output status indication
  • Accuracy
  • 1% of F.S.
  • Connection
  • Plug-in screw terminals
  • Model Number
  • icc211-i1-01
 

Icc211 For current output icc211-i1-01 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Icc211 For current output icc211-i1-01

Medium Voltage Current Transformer

Output and power supply on separately powered units, and between input and output on ... voltage pulse. 5. 4. 1. 2-wire current pulse.Voltage pulse. Current pulse. 5.1. Inhibit. Load ... No 2 Serangoon North Avenue 5, #06-01 Fu Yu Building.



Reliable and Safe Performance

Engineered using flame-retardant ABS material and featuring overload protection, the ICC211-i1-01 ensures continuous and secure operation in industrial settings. Its high mechanical life (10,000,000 cycles) assures long-term durability, while advanced insulation resistance and dielectric strength enhance safety during use.


Flexible Installation and Configuration

The device supports DIN rail mounting, plug-in screw terminals, and standard industrial module sizing, making installation straightforward. Whether your system requires current or voltage input, its easily configurable setup offers seamless integration into diverse industrial automation scenarios.


Clear Monitoring and Easy Maintenance

With power and output LED status indicators, users can quickly verify operational conditions at a glance. Its accurate performance (1% Full Scale) and fast response (<30 ms) guarantee reliable output monitoring. Maintenance is simplified by the modular, plug-in design and accessible terminal connections.

FAQs of Icc211 For current output icc211-i1-01:


Q: How do I install the ICC211-i1-01 current output relay?

A: The ICC211-i1-01 is designed for DIN rail mounting, simplifying installation in standard industrial control panels. Plug-in screw terminals facilitate quick wiring, and the standard module size ensures compatibility with most setups.

Q: What input signals are supported by the ICC211-i1-01?

A: The relay can be configured to accept either current or voltage input signals, increasing its adaptability for a variety of current and voltage monitoring applications.

Q: When should I use this relay in my automation system?

A: Use the ICC211-i1-01 for reliable current output monitoring, especially when fast response (<30 ms), high accuracy (1% F.S.), and overload protection are essential in your process control or industrial automation environment.

Q: Where can the ICC211-i1-01 be operated safely?

A: This device operates safely in ambient temperatures from -20C to +55C, with storage up to +70C, making it suitable for most industrial settings. The flame-retardant housing further enhances operational safety.

Q: What is the benefit of the LED indicators on the ICC211-i1-01?

A: The integrated power and output status LED indicators provide immediate visual feedback on relay operation, facilitating monitoring and troubleshooting during routine checks or system maintenance.

Q: How is overload protection implemented in the ICC211-i1-01?

A: Overload protection is a built-in feature that helps prevent relay damage under excessive load conditions, improving system reliability and extending the relays service life.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

MICOM P442318B3A0070B RELAY

MICOM P442318B3A0070B RELAY

Minimum Order Quantity : 1 Piece

Product Type : Relay

Theory : Other , Not Available

Color : White

Usage : Not Available

ABB REU610CVVHCNR RELAY

ABB REU610CVVHCNR RELAY

Minimum Order Quantity : 1 Piece

Product Type : Protection Relay

Theory : Other , Electromechanical

Color : Grey

Usage : Protection and control of electrical power systems

ALLEN BRADLEY MSR132EP SAFETY RELAY

ALLEN BRADLEY MSR132EP SAFETY RELAY

Minimum Order Quantity : 1 Piece

Product Type : Safety Relay

Theory : Other , Electromechanical Relay

Color : Red

Usage : Safety monitoring and control

SHREEM SPF-12T Series Automatic Power Factor Controller

SHREEM SPF-12T Series Automatic Power Factor Controller

Minimum Order Quantity : 1 Piece

Product Type : Automatic Power Factor Controller

Theory : Other , Microcontroller Based Switching

Color : Black & Grey

Usage : Automatic Power Factor Correction in Electrical Panels



Back to top