Icc211 For current output   icc211-i1-01
Icc211 For current output   icc211-i1-01
Icc211 For current output   icc211-i1-01
Icc211 For current output   icc211-i1-01
Icc211 For current output   icc211-i1-01
Icc211 For current output   icc211-i1-01
Icc211 For current output   icc211-i1-01
Icc211 For current output   icc211-i1-01

Icc211 For current output icc211-i1-01

MOQ : 1 Piece

Icc211 For current output icc211-i1-01 Specification

  • Protect Feature
  • Overload Protection
  • Ambient Temperature
  • -20C to +55C
  • Contact Form
  • SPDT (1c)
  • Power Consumption
  • < 0.9W
  • Dielectiric Strength
  • 2,000V AC/minute
  • Contact Resistance
  • 100 m
  • Contact Material
  • Silver Alloy
  • Coil Voltage
  • 24V DC
  • Working Temperature
  • -10C to +40C
  • Coil Power
  • 0.9W
  • Mechanical Life
  • 10,000,000 times
  • Product Type
  • Current Output Relay Module
  • Insulation Resistance
  • > 100 M (at 500V DC)
  • Theory
  • Electromagnetic Relay
  • Usage
  • Current Output Monitoring
  • Contact Load
  • 10A 250VAC/24VDC
  • Operate Time
  • 15 ms
  • Terminal Type
  • Screw type
  • Rated Voltage
  • AC 250V
  • Supply Terminal
  • 2 terminals
  • Size
  • Standard industrial module size
  • Color
  • Black and White
  • Dimension (L*W*H)
  • 90 mm 22.5 mm 70 mm
  • Weight
  • Approximately 110g
  • Input Signal
  • Current or voltage depending on configuration
  • Storage Temperature
  • -25C to +70C
  • Connection
  • Plug-in screw terminals
  • Output Current Range
  • 4-20mA
  • Response Time
  • < 30 ms
  • Accuracy
  • 1% of F.S.
  • Housing Material
  • Flame retardant ABS
  • Mounting Type
  • DIN Rail
  • Frequency
  • 50/60Hz
  • LED Indicator
  • Power and output status indication
  • Model Number
  • icc211-i1-01
 

Icc211 For current output icc211-i1-01 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Icc211 For current output icc211-i1-01

Medium Voltage Current Transformer

Output and power supply on separately powered units, and between input and output on ... voltage pulse. 5. 4. 1. 2-wire current pulse.Voltage pulse. Current pulse. 5.1. Inhibit. Load ... No 2 Serangoon North Avenue 5, #06-01 Fu Yu Building.



Reliable and Safe Performance

Engineered using flame-retardant ABS material and featuring overload protection, the ICC211-i1-01 ensures continuous and secure operation in industrial settings. Its high mechanical life (10,000,000 cycles) assures long-term durability, while advanced insulation resistance and dielectric strength enhance safety during use.


Flexible Installation and Configuration

The device supports DIN rail mounting, plug-in screw terminals, and standard industrial module sizing, making installation straightforward. Whether your system requires current or voltage input, its easily configurable setup offers seamless integration into diverse industrial automation scenarios.


Clear Monitoring and Easy Maintenance

With power and output LED status indicators, users can quickly verify operational conditions at a glance. Its accurate performance (1% Full Scale) and fast response (<30 ms) guarantee reliable output monitoring. Maintenance is simplified by the modular, plug-in design and accessible terminal connections.

FAQs of Icc211 For current output icc211-i1-01:


Q: How do I install the ICC211-i1-01 current output relay?

A: The ICC211-i1-01 is designed for DIN rail mounting, simplifying installation in standard industrial control panels. Plug-in screw terminals facilitate quick wiring, and the standard module size ensures compatibility with most setups.

Q: What input signals are supported by the ICC211-i1-01?

A: The relay can be configured to accept either current or voltage input signals, increasing its adaptability for a variety of current and voltage monitoring applications.

Q: When should I use this relay in my automation system?

A: Use the ICC211-i1-01 for reliable current output monitoring, especially when fast response (<30 ms), high accuracy (1% F.S.), and overload protection are essential in your process control or industrial automation environment.

Q: Where can the ICC211-i1-01 be operated safely?

A: This device operates safely in ambient temperatures from -20C to +55C, with storage up to +70C, making it suitable for most industrial settings. The flame-retardant housing further enhances operational safety.

Q: What is the benefit of the LED indicators on the ICC211-i1-01?

A: The integrated power and output status LED indicators provide immediate visual feedback on relay operation, facilitating monitoring and troubleshooting during routine checks or system maintenance.

Q: How is overload protection implemented in the ICC211-i1-01?

A: Overload protection is a built-in feature that helps prevent relay damage under excessive load conditions, improving system reliability and extending the relays service life.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

EASUN MIT104 PROTECTION HEALTHY RELAY

EASUN MIT104 PROTECTION HEALTHY RELAY

Minimum Order Quantity : 1 Piece

Product Type : Protection Healthy Relay

Usage : Protection and Healthy Indication Relay for Electrical Systems

Theory : Other , Electromagnetic Relay

Protect Feature : Other, Over Voltage, Under Voltage, Healthy Indication

ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)

ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)

Minimum Order Quantity : 1 Piece

Product Type : Protection Relay Display (only display module)

Usage : Protection relay display module for power systems

Theory : Other , Microprocessorbased digital protection

Protect Feature : Other, Overcurrent, Differential, Transformer Protection (via relay unit)

SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY

SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Product Type : Digital Generator Protection Relay

Usage : Generator Protection

Theory : Other , Microprocessor based digital relay

Protect Feature : Other, Differential, Overcurrent, Earth Fault, Loss of Excitation, Over/Under Voltage, Frequency Protection, Reverse Power, Vector Surge, Phase Balance, Overload protection

Schneider Multifunction Relay EOCR-FDE

Schneider Multifunction Relay EOCR-FDE

Minimum Order Quantity : 1 Piece

Product Type : Multifunction Electronic Over Current Relay

Usage : Motor Protection and Monitoring

Theory : Other , Current Relay / Electronic

Protect Feature : Other, Overcurrent, Underload, Phase Loss, Phase Sequence, Jam, Stall, Unbalance Protection