CUTLER HAMMER HND 65K HND312T32W 1200A 3POLE CIRCUIT BREAKER Specification

  • Breaking Capacity
  • 65kA @ 480VAC
  • Rated Short Circuit Breaking Current
  • 65kA @ 480VAC
  • Mechanical Life
  • 10,000 Operations (Typical)
  • Phase
  • Three Phase
  • Product Type
  • Molded Case Circuit Breaker (MCCB)
  • Installation Options
  • Panel Mounted / Fixed
  • Function
  • Circuit Protection, Overload and Short Circuit Protection
  • Poles Number
  • 3 Pole
  • Rated Voltage
  • 600V AC
  • Rated Current
  • 1200A
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • Instantaneous Trip
  • Temperature Protection
  • Yes, thermal-magnetic protection
  • Weight
  • Approximately 18 kg
  • Color
  • Black / Grey
  • Enclosure
  • Open Type
  • Interrupting Rating
  • 65,000 Amps @ 480VAC
  • Auxiliary Option
  • Auxiliary Switch Add-on Option
  • Frame Type
  • HND Series
  • Standards Compliance
  • UL Listed, IEC 60947-2
  • Operating Temperature Range
  • -20C to +40C
  • Model Number
  • HND312T32W
  • Trip Unit Type
  • Thermal-Magnetic
  • Connection Type
  • Front Connected / Bolt-On
  • Mounting Orientation
  • Vertical or Horizontal
 

CUTLER HAMMER HND 65K HND312T32W 1200A 3POLE CIRCUIT BREAKER Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 500 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About CUTLER HAMMER HND 65K HND312T32W 1200A 3POLE CIRCUIT BREAKER

CUTLER HAMMER HND 65K HND312T32W 1200A 3POLE CIRCUIT BREAKER


HND Frame Style, Molded Case Circuit Breaker, Electronic Non-Interchangeable Trip Unit(Digitrip RMS 310), LSI Trip Unit Functions, 1200 Ampere at 40 Degree Celsius, 3 Pole, 600VAC @ 50/60HZ, High Interrupting Ratings: 100 Kiloampere @ 240VAC, 65 Kiloampere @ 480VAC, 35 Kiloampere @ 600VAC, Rating Plug Not Included.





Reliable High Capacity Protection

Engineered for environments that demand high interrupting ratings, the HND312T32W circuit breaker delivers robust protection against overloads and short circuits. Its instantaneous trip curve ensures fast response, offering safety and reliability in critical installations. With thermal-magnetic trip units and a mechanical life of 10,000 operations, it delivers dependable, long-term service.


Versatile Installation and Connectivity

Designed for maximum flexibility, this circuit breaker features front-connected, bolt-on terminals for straightforward integration. Suitable for both vertical and horizontal mounting, it can be panel-mounted and fixed to suit diverse electrical configurations. The open-type enclosure and auxiliary switch add-on options enhance adaptability for control and signaling purposes.


Certified, Compliant, and Efficient

Meeting UL Listed and IEC 60947-2 standards, the HND312T32W ensures adherence to rigorous safety and performance benchmarks. With a rated operational temperature range and a sturdy build, it supports high-demand applications in commercial and industrial environments across India and beyond.

FAQ's of CUTLER HAMMER HND 65K HND312T32W 1200A 3POLE CIRCUIT BREAKER:


Q: How does the CUTLER HAMMER HND312T32W provide circuit protection?

A: This circuit breaker uses a thermal-magnetic trip unit to protect circuits from overloads and short circuits. When excessive current or a fault is detected, it trips instantly, breaking the circuit and preventing damage to equipment or infrastructure.

Q: What are the installation options for the HND 65K HND312T32W?

A: The circuit breaker is panel mounted and can be installed in either a vertical or horizontal orientation. Its front-connected, bolt-on terminals simplify installation in various electrical panels and fixed setups.

Q: When should I consider using the HND312T32W circuit breaker?

A: This breaker is ideal for industrial or commercial settings where high breaking capacity is required, up to 65,000 Amps at 480VAC and 1200A rated current, making it suitable for critical power distribution protection.

Q: Where can the HND312T32W circuit breaker be used?

A: The product is suitable for indoor installations in environments where reliable circuit protection is necessary, such as manufacturing sites, commercial buildings, or specialized electrical setups within its operating temperature range of -20C to +40C.

Q: What is the benefit of the auxiliary switch add-on option?

A: Adding an auxiliary switch provides remote indication or control capability, enabling advanced monitoring and integration into building management or automation systems.

Q: What process should be followed for maintenance of the circuit breaker?

A: Regular inspections for physical damage, testing the mechanical operation, and ensuring connections remain secure are recommended. Always follow safety protocols and consult the manufacturer's maintenance guidelines for detailed instructions.

Q: How does compliance with UL and IEC standards benefit users?

A: Compliance signifies that the product meets stringent safety, quality, and performance benchmarks, ensuring reliable operation and facilitating easier approval during inspections or audits in professional environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Circuit breaker Category

ABB XT4H 250 (CCAA041527) CIRCUIT BREAKER

ABB XT4H 250 (CCAA041527) CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Function : Protection and Control

Rated Frequency : 50/60 Hz

Temperature Protection : Adjustable Thermal Protection

Curves : H (High) Breaking Capacity Curve

Rated Current : 250 A

DISJONCTEUR KAL36125 125A 3P CIRCUIT BREAKER

DISJONCTEUR KAL36125 125A 3P CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Function : Circuit Protection

Rated Frequency : 50/60 Hz

Temperature Protection : Yes, with builtin thermal protection

Curves : Thermal Magnetic

Rated Current : 125A

CUTLER HAMMER ND 50K ND312T56W 1200A 3POLE CIRCUIT BREAKER

CUTLER HAMMER ND 50K ND312T56W 1200A 3POLE CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Function : Circuit Protection, Overload and Short Circuit Protection

Rated Frequency : 50/60 Hz

Temperature Protection : Yes (ThermalMagnetic)

Curves : ND (Instantaneous Trip Adjustment)

Rated Current : 1200A

SQUARE D HD150 (HDL36150) 150A CIRCUIT BREAKER

SQUARE D HD150 (HDL36150) 150A CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Function : Protection against overloads and short circuits

Rated Frequency : 50/60 Hz

Temperature Protection : Integrated thermalmagnetic protection

Curves : H

Rated Current : 150A