ALLEN BRADLEY 193-ECPM3 RELAY
ALLEN BRADLEY 193-ECPM3 RELAY
ALLEN BRADLEY 193-ECPM3 RELAY
ALLEN BRADLEY 193-ECPM3 RELAY
ALLEN BRADLEY 193-ECPM3 RELAY
ALLEN BRADLEY 193-ECPM3 RELAY
ALLEN BRADLEY 193-ECPM3 RELAY
ALLEN BRADLEY 193-ECPM3 RELAY

ALLEN BRADLEY 193-ECPM3 RELAY

MOQ : 1 Piece

ALLEN BRADLEY 193-ECPM3 RELAY Specification

  • Dielectiric Strength
  • 2500 V AC for 1 min
  • Ambient Temperature
  • -20C to +60C
  • Contact Form
  • 1 NO + 1 NC
  • Coil Voltage
  • Not Applicable (Electronic relay)
  • Coil Power
  • Not Applicable (Electronic relay)
  • Power Consumption
  • Approx. 1.2 W
  • Protect Feature
  • Phase Loss, Overload, Phase Imbalance
  • Mechanical Life
  • 10 Million Operations
  • Contact Material
  • Silver Alloy
  • Working Temperature
  • -20C to +60C
  • Contact Resistance
  • 100 m
  • Product Type
  • Electronic Overload Relay
  • Insulation Resistance
  • > 100 M at 500 VDC
  • Theory
  • Electronic Monitoring
  • Usage
  • Electronic Protection Relay
  • Contact Load
  • 5 A at 250 V AC
  • Operate Time
  • Typically < 30 ms
  • Terminal Type
  • Screw Terminal
  • Rated Voltage
  • 600 V AC/DC
  • Supply Terminal
  • Top/Bottom Side Terminals
  • Size
  • Standard Module Size
  • Color
  • Grey
  • Dimension (L*W*H)
  • 45 mm x 80 mm x 110 mm
  • Weight
  • Approx. 250 g
  • LED Status Indication
  • Yes
  • Short Circuit Protection
  • Requires external short circuit protection
  • Reset Type
  • Manual/Automatic selectable
  • Trip Class
  • 5, 10, 20, 30 selectable
  • Application
  • Motor Protection and Equipment Safety
  • Adjustable Current Range
  • 0.1 - 30 A (model dependent)
  • Standards
  • UL, CSA, CE approved
  • Humidity Range
  • 5% to 95% RH, non-condensing
  • Mounting Type
  • DIN rail or panel mount
 

ALLEN BRADLEY 193-ECPM3 RELAY Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ALLEN BRADLEY 193-ECPM3 RELAY

ALLEN BRADLEY 193-ECPM3 RELAY


The Allen-Bradley 193-ECPM3 DIN Rail/panel mounting adapter is a mounting adapter module from the Bulletin 193-EC electronic motor protection relay add-on accessories family. The 193-ECPM3 adapter is designed to allow for the easy DIN Rail or panel mounting of the relay devices.



Advanced Motor and Equipment Safety

Engineered for modern industry, the ALLEN BRADLEY 193-ECPM3 relay offers extensive capability for motor protection and operational safety. Selectable trip classes and comprehensive protection against phase loss, imbalance, and overload ensure reliability and versatility in a broad range of settings.


Versatile Installation and Effortless Monitoring

This relay simplifies integration with both DIN rail and panel mounting options, while tool-free screw terminals streamline wiring. The bright LED status indicator allows for real-time monitoring, ensuring rapid response to operational changes or protection events.

FAQ's of ALLEN BRADLEY 193-ECPM3 RELAY:


Q: How does the ALLEN BRADLEY 193-ECPM3 provide motor protection?

A: It offers comprehensive electronic protection by monitoring for overload, phase loss, and phase imbalance. Its adjustable trip classes and current range allow for precise tuning based on your motor's specifications, enhancing safety and extending equipment life.

Q: What are the selectable trip classes, and when should each be used?

A: Trip classes 5, 10, 20, and 30 are selectable, representing the time taken for the relay to trip under overload. Faster classes (e.g., 5) are ideal for sensitive motors, while slower classes (e.g., 30) suit applications tolerating brief overloads.

Q: Where can this relay be installed?

A: The 193-ECPM3 is suitable for both DIN rail and panel mounting, offering flexibility in installation within control panels or machinery, depending on your facility's requirements.

Q: What process is involved in resetting the relay after a trip event?

A: You can select either manual or automatic reset modes. In manual mode, the relay requires user intervention, while automatic mode restores operation once fault conditions are cleared, streamlining workflow in automated environments.

Q: What are the benefits of the LED status indication feature?

A: LED status indication provides instant visual feedback on relay and equipment status, helping operators quickly identify and address issues, thereby reducing downtime and supporting preventive maintenance.

Q: What external protection is required for this relay?

A: While the relay monitors overload and phase errors, an external short circuit protective device must be installed to fully safeguard connected components.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

C.t.connections For Oc Relay  Adr111a

C.t.connections For Oc Relay Adr111a

Price Range 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Protection and control applications

Product Type : Current Transformer Connection for OC Relay

Insulation Resistance : >100 M at 500V DC

Protect Feature : Other, Overcurrent Protection

CONZERV EM 3480 RELAY

CONZERV EM 3480 RELAY

Minimum Order Quantity : 1 Piece

Usage : Energy Meter Relay for monitoring and controlling electrical circuits

Product Type : Electrical Monitoring Relay

Insulation Resistance : > 100 M at 500V DC

Protect Feature : Other, Overload, Short Circuit Protection

ABB RET670 (BIG SCREEN) PROTECTION RELAY (ONLY DISPLAY)

ABB RET670 (BIG SCREEN) PROTECTION RELAY (ONLY DISPLAY)

Minimum Order Quantity : 1 Piece

Usage : Protection and control for transformer applications

Product Type : Protection Relay (Display Only)

Insulation Resistance : >100 M at 500 V DC

Protect Feature : Other, Highimpedance Differential and Transformer Protection

MICOM P143 P14331007M0468J PROTECTION RELAY (NOT WORKING)

MICOM P143 P14331007M0468J PROTECTION RELAY (NOT WORKING)

Minimum Order Quantity : 1 Piece

Usage : Protection relay for electrical systems

Product Type : Numerical Protection Relay (Distance Protection, Feeder Protection, Breaker Failure, etc.)

Insulation Resistance : >100M at 500V DC

Protect Feature : Other, Distance, Overcurrent, Earth Fault & Breaker Failure Protection



Back to top