ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)
ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)
ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)
ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)
ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)
ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)
ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)
ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)

ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)

MOQ : 1 Piece

ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY) Specification

  • Coil Voltage
  • N/A (display only)
  • Dielectiric Strength
  • 2 kV RMS, 50 Hz, 1 min
  • Contact Resistance
  • N/A (display only)
  • Ambient Temperature
  • -25C to +55C
  • Working Temperature
  • -25C to +55C
  • Protect Feature
  • Overcurrent, Differential, Transformer Protection (via relay unit)
  • Power Consumption
  • <15 W (display only)
  • Mechanical Life
  • Designed for over 10 years operation
  • Coil Power
  • N/A (display only)
  • Contact Form
  • N/A (only display)
  • Contact Material
  • N/A (display only)
  • Product Type
  • Protection Relay Display (only display module)
  • Insulation Resistance
  • > 100 M at 500 V DC
  • Theory
  • Microprocessor-based digital protection
  • Usage
  • Protection relay display module for power systems
  • Contact Load
  • N/A (only display, no switching contacts)
  • Operate Time
  • Less than 20 ms (typical, depends on system integration)
  • Terminal Type
  • Plug-in terminal blocks
  • Rated Voltage
  • 110-250 V DC / 110-240 V AC
  • Supply Terminal
  • Rear connection
  • Size
  • Small screen compartment module
  • Color
  • Grey front, black housing
  • Dimension (L*W*H)
  • 228 mm x 177 mm x 185 mm (module overall)
  • Weight
  • Approx. 1.2 kg
  • Protection Class
  • IP40 (front), IP20 (rear)
  • Communication Ports
  • Front USB/RS232 service port (display configuration, depends on relay hardware)
  • Backlight
  • LED backlit
  • Screen Type
  • LCD graphical display (small screen)
  • Compatibility
  • For RET670 series protection relays
  • Language Support
  • Multilingual display option
  • Display Features
  • LED indicators, function keys
  • Relay Support
  • Supports RET670 functions including transformer differential, distance, and backup overcurrent (as per main relay configuration)
  • Mounting Style
  • Flush mounting in relay case
  • Display Resolution
  • 128 x 64 pixels
 

ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY) Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)

ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)


RET670 IEDs provide customized or pre-configured protection solutions for any type of transformer and shunt reactor application. The customized RET670 gives you the freedom to select functionality entirely according to your needs. The pre-configured RET670 variants simplify handling since the basic functionality is included and pre-configured. If needed, you can add optional functions to increase the functionality of the pre-configured RET670 IEDs to meet the specific requirements of your transformer or shunt reactor.



Compact and Robust Display Solution

The ABB RET670 (Small Screen) Protection Relay Display is designed to withstand demanding substation environments, featuring a secure flush-mount installation and reliable performance over extended service life. Its small form factor fits seamlessly into RET670 relay cases, while its IP-rated front offers robust protection against dust and accidental contact.


User-Friendly Interface and Multilingual Options

Navigating protection relay information is efficient with the 128 x 64 pixels graphical LCD, LED backlighting, intuitive function keys, and clear LED indicators. Multiple language options allow operators from varied backgrounds to configure and monitor system parameters comfortably, enhancing both accessibility and security.


Versatile Connectivity and Fast Response

A front USB/RS232 service port (depending on relay configuration) streamlines relay parameterization and diagnostics. With a typical operate time of under 20 ms and low power usage, the display module supports rapid protection signaling, vital for minimizing system downtime and ensuring reliable grid operation.

FAQ's of ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY):


Q: How is the ABB RET670 (Small Screen) display module installed?

A: The display module is designed for flush mounting within the RET670 relay case, utilizing rear plug-in terminal blocks for secure power and data connections. This enables quick and straightforward integration with new or existing RET670 series protection relays.

Q: What are the primary usage benefits of this display module?

A: This module provides real-time visualization of relay status, events, and system protection functions, such as transformer differential and backup overcurrent. Its clear display and LED indicators facilitate quick decision-making and efficient operation in power system environments.

Q: What protection features are supported through the display?

A: While the module itself does not offer direct protection, it visually represents RET670 relay protection features including transformer differential, distance protection, and overcurrent functions, as configured by the main relay unit.

Q: Where can I use the ABB RET670 (Small Screen) display module?

A: It is specifically designed for use within substations and industrial power systems where RET670 series relays operate, providing robust monitoring and control in environments with ambient temperatures from -25C to +55C.

Q: How do operators interact with the display?

A: Operators use function keys and view status through the LCD graphical display enhanced by LED backlighting. Multilingual support ensures clear messaging, while LED indicators provide immediate visual feedback on relay and system status.

Q: What is the process for configuring or servicing the display?

A: Access to configuration and diagnostics is available through the front USB or RS232 service port (pending relay hardware support), allowing engineers to update parameters and service the module efficiently with compatible devices.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

Over Current Earth Fault Relay  03118738

Over Current Earth Fault Relay 03118738

Price Range 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Operate Time : <30 ms

Product Type : Over Current Earth Fault Relay

Dimension (L*W*H) : 96mm x 96mm x 110mm

Rated Voltage : 110V/220V AC

ABB REL511 RELAY

ABB REL511 RELAY

Minimum Order Quantity : 1 Piece

Operate Time : < 30 ms

Product Type : Numerical Line Distance Protection Relay

Dimension (L*W*H) : 483mm x 266mm x 130mm

Rated Voltage : 110240 V AC/DC

ABB RET316 4 RELAY

ABB RET316 4 RELAY

Minimum Order Quantity : 1 Piece

Operate Time : <35 ms

Product Type : Numerical Motor Protection Relay

Dimension (L*W*H) : 227 x 262 x 70 mm

Rated Voltage : 110240 VAC / VDC

MICOM P64291AA6M0060P RELAY

MICOM P64291AA6M0060P RELAY

Minimum Order Quantity : 1 Piece

Operate Time : < 20 ms

Product Type : Protection Relay

Dimension (L*W*H) : 255 mm x 106 mm x 138 mm

Rated Voltage : 110 VDC



Back to top