ABB REC650 PROTECTION RELAY (ONLY DISPLAY) Specification

  • Dielectiric Strength
  • 2.0 kV, 50/60 Hz, 1 min (inputs/outputs to earth)
  • Contact Form
  • NO/NC (modular outputs)
  • Coil Power
  • Not applicable for display unit
  • Power Consumption
  • <25 W (display unit only)
  • Protect Feature
  • Display interface for protection operation monitoring
  • Mechanical Life
  • >107 operations (relay contacts)
  • Coil Voltage
  • Internal electronics powered (not applicable for display unit)
  • Contact Material
  • Silver alloy
  • Working Temperature
  • -25C to +70C (storage)
  • Contact Resistance
  • <100 m
  • Ambient Temperature
  • -25C to +55C (operational)
  • Product Type
  • Digital Protection Relay (Display Unit)
  • Insulation Resistance
  • >100 M @ 500 V DC
  • Theory
  • Microprocessor-based relay
  • Usage
  • Transformer protection (display unit only for REC650)
  • Contact Load
  • 10 A / 250 V AC, 8 A / 24 V DC (relay outputs)
  • Operate Time
  • Typical 15 ms (relay output response)
  • Terminal Type
  • Plug-in terminals on rear side
  • Rated Voltage
  • 24-250 V AC/DC (auxiliary supply range)
  • Supply Terminal
  • Rear connection, dedicated power terminals
  • Size
  • 1/2 x 19 rack (modular system)
  • Color
  • Grey with black frame
  • Dimension (L*W*H)
  • 244 mm x 108 mm x 341 mm (approximately)
  • Weight
  • Approx. 2.5 kg (display unit only)
  • Front Panel Controls
  • Tactile pushbuttons for menu navigation, LEDs for indication
  • Communication Ports
  • Ethernet, Serial (front USB and rear communication) for configuration and monitoring
  • Operating Frequency
  • 50/60 Hz environments
  • Event and Fault Records
  • Available via the display and communication ports
  • Language Support
  • Multi-language (English default)
  • Supported Protocols
  • IEC 61850, Modbus, DNP3, IEC 60870-5-103
  • Mounting Options
  • Flush, semi-flush, and rack mounting compatible
  • Degree of Protection
  • Front: IP54, Rear: IP20
  • Display Type
  • Graphical LCD, 8 lines with backlight
  • Standards Compliance
  • IEC 60255, CE marked
  • Time Synchronization
  • SNTP, IRIG-B compatible
  • Firmware Upgradeability
  • Field upgradeable via front USB
 

ABB REC650 PROTECTION RELAY (ONLY DISPLAY) Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ABB REC650 PROTECTION RELAY (ONLY DISPLAY)

ABB REC650 PROTECTION RELAY (ONLY DISPLAY)


For optimized control and reliable operation of your switchyard, the REC650 is your best choice for sub-transmission applications. REC650 offers an optimum 'off-the-shelf solution for apparatus control of a single breaker in single and double busbar arrangements.



Intuitive Display and Navigation

The REC650's front panel features a large graphical LCD with eight lines of information and a backlight, providing clear visibility even in dim environments. Tactile pushbuttons enable efficient menu navigation and configuration, while dedicated LEDs offer immediate operational feedback, making management and event monitoring straightforward and user-friendly.


Versatile Communication and Integration

With Ethernet and serial ports (front USB and rear connections), the display supports configuration and real-time monitoring. Compatible with IEC 61850, Modbus, DNP3, and IEC 60870-5-103, it integrates effortlessly into modern substation automation systems, ensuring dependable communication and data accessibility for engineers and operators.


Rugged Design and Flexible Mounting

Designed for harsh environments, the REC650 display offers IP54 protection at the front and IP20 at the rear. Its modular half-19" rack size fits flush, semi-flush, or rack mounting, making it apt for new installations or upgrades. The robust build withstands temperature extremes and high dielectric strength, ensuring long operational life and component reliability.

FAQ's of ABB REC650 PROTECTION RELAY (ONLY DISPLAY):


Q: How can I configure and monitor the REC650 display unit?

A: The REC650 display can be configured and monitored via its intuitive graphical LCD using front panel pushbuttons, or remotely through Ethernet and serial communication ports. The front USB port simplifies configuration updates and monitoring, while supported protocols like IEC 61850 and Modbus facilitate integration with supervisory control systems.

Q: What installation options are available for the REC650 display unit?

A: The unit is designed for flexible deployment and supports flush mounting, semi-flush installation, and standard rack mounting. This adaptability allows seamless integration into various panel layouts and switchgear configurations-for both retrofits and new projects.

Q: When should firmware updates be performed on the display unit?

A: Firmware upgrades should be performed during scheduled maintenance or as recommended by ABB for feature enhancements or security updates. Upgrades are straightforward using the front USB port, ensuring improved performance without needing to dismantle the unit.

Q: Where are the event and fault records accessed?

A: Event and fault records are accessible directly through the graphical display on the unit or remotely via the supported communication ports. This feature enables operators to promptly review system operation history and address any incidents quickly.

Q: What are the benefits of the display unit's protection rating and mechanical features?

A: The REC650 display offers robust environmental protection with an IP54 rated front and IP20 rear, ensuring durability against dust, moisture, and accidental impacts. Its mechanical reliability is further established by a contact life exceeding 10 million operations and high insulation resistance, making it suitable for demanding substations.

Q: How does the REC650 ensure interoperability in substation environments?

A: With multi-protocol support (IEC 61850, Modbus, DNP3, IEC 60870-5-103) and time synchronization via SNTP or IRIG-B, the REC650 display ensures smooth integration into diverse substation automation systems, enabling accurate data sharing and synchronized event logging.

Q: What advantages does multi-language support offer for operators in India?

A: Multi-language support, with English as the default, ensures that the REC650 display is accessible to diverse operator teams, reducing training time and minimizing user errors-particularly in installations across multilingual regions in India.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

MICOM P642912A3M0050P RELAY

MICOM P642912A3M0050P RELAY

Minimum Order Quantity : 1 Piece

Dielectiric Strength : 1500V AC, 1 minute

Color : Black

Usage : Electrical Panels, Industrial Automation

Size : Other, Standard

Operate Time : 15 ms

ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)

ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)

Minimum Order Quantity : 1 Piece

Dielectiric Strength : 2 kV, 50/60Hz, 1 min

Color : Grey

Usage : Protection relay in power systems

Size : Other, Standard Compact (Small Relay)

Operate Time : <30 ms

PiLZ PNOZ X3 SAFETY RELAYS

PiLZ PNOZ X3 SAFETY RELAYS

Minimum Order Quantity : 1 Piece

Dielectiric Strength : 2.5 kV, 50 Hz, 1 min

Color : Yellow

Usage : Safety relay for monitoring emergency stop, safety gates, and light barriers

Size : Other, Compact (Approx. 87 x 22.5 x 121 mm)

Operate Time : < 20 ms

SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY

SIEMENS 7SD6101-5BB99-0BA0/EE (BF1108065127) PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Dielectiric Strength : 2 kV, 50 Hz, 1 min

Color : Grey

Usage : Feeder protection, Distance protection, Line differential protection

Size : Other, 19 rack, 4U height

Operate Time : Typically 20 ms



Back to top