SQUARE D POWER PACT HD 150 HDL36150 150A 3 POLE CIRCUIT BREAKER Specification

  • Breaking Capacity
  • 50 kA @ 415V AC
  • Rated Short Circuit Breaking Current
  • 50 kA
  • Mechanical Life
  • 20000 operations
  • Phase
  • Three Phase
  • Rated Short Circuit Making Current
  • 105 kA
  • Product Type
  • Moulded Case Circuit Breaker (MCCB)
  • Installation Options
  • Panel Mount
  • Function
  • Circuit Protection
  • Poles Number
  • 3 Pole
  • Rated Voltage
  • 600V AC Max
  • Rated Current
  • 150A
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • HDL (Fixed Trip Unit)
  • Temperature Protection
  • Yes (Thermal-Magnetic)
  • Weight
  • 3.8 kg
  • Color
  • Black/Grey
  • Handle Type
  • Rotary Handle (standard)
  • Mounting Orientation
  • Any position
  • Frame Size
  • HD 150 Frame
  • Application
  • Industrial, Commercial Distribution
  • Series
  • PowerPact HD
  • Standards
  • IEC 60947-2, UL 489, CSA C22.2 No. 5
  • Trip Indicator
  • Mechanical ON/OFF/Trip indicator
  • Protection Class
  • IP40 (front) / IP20 (terminals)
  • Terminal Type
  • Lug (Line and Load)
  • Trip Unit Technology
  • Thermal-Magnetic Fixed
  • Short Circuit Protection
  • Yes
  • Operating Temperature
  • -25C to +70C
  • Accessory Options
  • Shunt Trip, Auxiliary Switch, Alarm Switch
  • Electrical Life
  • 10000 operations
 

SQUARE D POWER PACT HD 150 HDL36150 150A 3 POLE CIRCUIT BREAKER Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 500 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About SQUARE D POWER PACT HD 150 HDL36150 150A 3 POLE CIRCUIT BREAKER

SQUARE D POWER PACT HD 150 HDL36150 150A 3 POLE CIRCUIT BREAKER


The HDL36150 is a 3-pole PowerPact H-frame unit-mount thermal-magnetic current limiting Circuit Breaker designed to protect electrical systems from damage caused by overloads and short-circuits. This circuit breaker is designed to open and close a circuit by non-automatic means and to open the circuit automatically on a predetermined over-current. The PowerPact H-frame circuit breaker is equipped with dual-break rotating contacts that reduce the amount of peak current during a short-circuit fault. This reduces the let-through currents and enhances equipment protection. The H-frame circuit breaker has an over-center toggle mechanism providing quick-make, quick-break operation. The operating mechanism is also trip-free, which allows tripping even when the circuit breaker handle is held in the ON position. The H-frame circuit breaker has an integral push-to-trip button in the cover to manually trip the circuit breaker. It is suitable for reverse connection.

  • 14kA at 600VAC Interrupting rating
  • 900A Hold and 1700A trip current


Reliable Circuit Protection for Harsh Environments

PowerPact HD circuit breakers are engineered to withstand rigorous operational demands. Thanks to its -25C to +70C temperature range, high short-circuit ratings, and robust thermal-magnetic protection, the HDL36150 ensures your critical electrical applications remain operational and safe, even in challenging industrial settings. The breaker's front IP40 and terminal IP20 ratings guard against dust and accidental contact, securing personnel and equipment.


Flexible Installation and Superior Performance

The HDL36150's panel mount design and suitability for any mounting orientation provide installation flexibility for modern electrical panels. The standard rotary handle enhances operational convenience and safety, while the mechanical ON/OFF/Trip indicator gives clear status updates. A choice of accessory options, like shunt trip or auxiliary switches, allows seamless integration into distribution networks, facilitating monitoring and control.

FAQ's of SQUARE D POWER PACT HD 150 HDL36150 150A 3 POLE CIRCUIT BREAKER:


Q: How does the PowerPact HD HDL36150 circuit breaker provide short-circuit protection?

A: The HDL36150 utilizes thermal-magnetic trip unit technology to detect and interrupt short circuits quickly. Its high breaking capacity of 50 kA at 415V AC ensures reliable protection of three-phase electrical systems against short-circuit and overload faults, preventing equipment damage and fire hazards.

Q: What are the installation options and requirements for this circuit breaker?

A: The PowerPact HD HDL36150 is designed for panel mounting and supports installation in any orientation. It features lug terminals for both line and load connections, allowing easy integration into new or existing panels in industrial or commercial environments.

Q: When should I use the HDL36150 circuit breaker in my facility?

A: You should use the HDL36150 when you require a 150A, 3-pole circuit breaker compliant with IEC 60947-2, UL 489, and CSA C22.2 No. 5 standards, especially in applications needing high breaking capacity (50 kA), robust thermal-magnetic protection, and flexible installation for three-phase systems.

Q: Where can this breaker be used for optimal performance?

A: The HDL36150 excels in industrial or commercial distribution systems where reliable circuit protection is vital. Its environmental ratings (IP40 front, IP20 terminals) make it suitable for indoor electrical panels, protecting against dust and accidental contact in manufacturing plants, commercial buildings, and infrastructure projects.

Q: What benefits does the mechanical ON/OFF/Trip indicator offer?

A: The built-in mechanical indicator provides clear, immediate visual feedback of the breaker's status (ON, OFF, or Trip). This feature improves safety and maintenance efficiency by allowing operators to quickly identify circuit interruptions, aiding rapid troubleshooting and minimizing downtime.

Q: How can users enhance functionality with auxiliary accessories?

A: The HDL36150 supports accessories such as shunt trips, auxiliary switches, and alarm switches. These options enable remote operation, status monitoring, and system integration, making the breaker adaptable for advanced control and safety strategies in complex electrical networks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Circuit breaker Category

ALLEN BRADLEY 140U-Q3X3 600A 3POLE MCCB

ALLEN BRADLEY 140U-Q3X3 600A 3POLE MCCB

Minimum Order Quantity : 1 Piece

Mechanical Life : 10,000 operations

Rated Voltage : 690V AC

Rated Frequency : 50/60Hz

Phase : Three Phase

Poles Number : Other, 3 Pole

SCHNEIDER POWERPACT QJ 200 CIRCUIT BREAKER

SCHNEIDER POWERPACT QJ 200 CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Mechanical Life : 10,000 operations

Rated Voltage : 240/480V AC

Rated Frequency : 50/60 Hz

Phase : Three Phase

Poles Number : Other, 3 Pole

Air Circuit Breaker (Acb)

Air Circuit Breaker (Acb)

Minimum Order Quantity : 1 , , Piece

Mechanical Life : 10000 cycles

Rated Voltage : 415 V AC

Rated Frequency : 50/60 Hz

Phase : other, 3

Poles Number : 3

FPE NE233040 3 POLE AIR CIRCUIT BREAKER

FPE NE233040 3 POLE AIR CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Mechanical Life : 10,000 operations

Rated Voltage : 690V AC

Rated Frequency : 50/60 Hz

Phase : Three Phase

Poles Number : Other, 3 Pole