SCHNEIDER METSEPM5110 POWER LOGIC
SCHNEIDER METSEPM5110 POWER LOGIC
SCHNEIDER METSEPM5110 POWER LOGIC
SCHNEIDER METSEPM5110 POWER LOGIC
SCHNEIDER METSEPM5110 POWER LOGIC
SCHNEIDER METSEPM5110 POWER LOGIC
SCHNEIDER METSEPM5110 POWER LOGIC
SCHNEIDER METSEPM5110 POWER LOGIC

SCHNEIDER METSEPM5110 POWER LOGIC

MOQ : 1 Piece

SCHNEIDER METSEPM5110 POWER LOGIC Specification

  • Mounting Type
  • Panel Mount
  • Frequency
  • 45 to 65 Hz
  • Control Type
  • Digital
  • Load Capacity
  • Up to 6 A Rated current per phase
  • Connectivity Type
  • RS485 (Modbus RTU)
  • Automation Grade
  • Automatic
  • Weight
  • Approx. 270g
  • Phase
  • 3 Phase, Single Phase
  • IP Rating
  • IP54 (front panel), IP20 (rear)
  • Sensor Type
  • Current, Voltage
  • Processor Type
  • Embedded microcontroller
  • Features
  • Multiple energy measurement, THD, Digital communication, Compact design
  • Application
  • Energy metering, Energy monitoring, Electrical panel integration
  • Screen Size
  • LED display, 4 Lines x 8 digits
  • Material
  • Plastic/Polycarbonate (Front face), Flame Retardant material
  • Power
  • Self powered via measured voltage, auxiliary not required
  • Temperature
  • Operating: -25C to +70C
  • Voltage
  • Rated measuring voltage: 63.5 to 277 V Line to Neutral, 110 to 480 V Line to Line AC
  • Data Logging
  • Min/Max values, Energy logging
  • Accuracy
  • Class 1 (Active energy), Class 2 (Reactive energy)
  • Supply Voltage
  • 110-415 V AC (direct input), up to 480 V L-L
  • Industry Certifications
  • CE, RoHS, UL
  • Display Type
  • LCD - White backlight
  • Compliance Standards
  • IEC 62053-21/22, IEC 61010-1
  • Output Type
  • Pulse output (SO, kWh/kVARh selectable)
  • Input Current Range
  • 1-6 A AC
  • Clock
  • Real-time clock for timestamping
  • Power Consumption
  • < 5 VA
  • Alt Model No.
  • METSEPM5110
  • Model
  • PowerLogic PM5110
  • Dimensions
  • 96 x 96 x 80 mm (panel cutout 92 x 92 mm)
  • Terminal Type
  • Screw-type terminals
 
 

About SCHNEIDER METSEPM5110 POWER LOGIC

SCHNEIDER METSEPM5110 POWER LOGIC


The METSEPM5110 is a 1-output Power Meter for energy cost and basic network management applications providing the measurement capabilities needed to allocate energy usage, perform tenant metering and sub-billing, pin-point energy savings, optimize equipment efficiency and utilization and perform a high level assessment of the power quality in an electrical network.



Advanced Energy Monitoring Simplified

The METSEPM5110 offers multiple energy measurement capabilities, real-time data logging, and a digital display with clear, four-line readouts. With support for both kWh and kVARh pulse outputs, it helps users accurately track and manage energy consumption across diverse applications. Designed for straightforward integration into electrical panels, this device empowers users to optimize efficiency and reduce operational costs.


Reliable and Safe Integration

Engineered with user safety and compliance in mind, the PM5110 meets international standards including IEC 62053-21/22 and carries certifications like CE, RoHS, and UL. Its IP54-rated front panel and flame-retardant construction ensure resilience in demanding environments, while screw-type terminals and panel mount design simplify installation and maintenance for system integrators and end-users alike.

FAQ's of SCHNEIDER METSEPM5110 POWER LOGIC:


Q: How is the PowerLogic PM5110 installed in electrical panels?

A: The PM5110 is designed for panel mounting using a 96 x 96 mm front cutout (92 x 92 mm required). Its screw-type terminals allow secure wiring of voltage and current inputs, making it suitable for quick integration into new or existing panels.

Q: What types of measurements can the METSEPM5110 perform?

A: This meter can measure a variety of electrical parameters, including active and reactive energy (with Class 1 and 2 accuracy respectively), current, voltage, frequency, and total harmonic distortion (THD). Minimum and maximum values are logged for enhanced monitoring.

Q: When should I use the kWh or kVARh pulse output option?

A: Select the kWh pulse output for tracking active energy consumption, or kVARh for reactive energy, based on your monitoring needs. The pulse output is especially beneficial for connecting the meter to a building management system or data acquisition device for automated recording.

Q: What are the connectivity options for data communication?

A: The PM5110 features RS485 communication with Modbus RTU protocol, enabling remote data retrieval and integration into industrial automation or monitoring systems, enhancing efficiency and data-driven decision-making.

Q: Where can the METSEPM5110 be used?

A: It is ideal for industrial and commercial facilities in India and worldwide, suitable for energy monitoring, sub-metering, and integration into electrical distribution panels across a wide voltage and frequency range (110-480 V AC, 45-65 Hz).

Q: How does the device ensure operational reliability and safety?

A: With compliance to IEC and UL standards, robust plastic/polycarbonate construction, flame retardance, and IP54/IP20 protection, the PM5110 is built for safe, long-term use in challenging operating environments.

Q: What benefits does the PowerLogic PM5110 offer to users?

A: The device provides accurate, real-time energy data, supports multi-phase power systems, helps reduce energy costs through monitoring, and simplifies compliance reporting. Its digital features and compact design support seamless panel integration and easy operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Schneider Electric Magelis PLC & HMI Category

J. Schneider Elektrotechnik gmbh Competent 00091562

J. Schneider Elektrotechnik gmbh Competent 00091562

Minimum Order Quantity : 1 Piece

Mounting Type : DIN Rail

Frequency : 50/60 Hz

Voltage : 230 V AC input

Control Type : Electronic

Connectivity Type : Terminal Connection

SCHNEIDER PM210MG POWER LOGIC

SCHNEIDER PM210MG POWER LOGIC

Minimum Order Quantity : 1 Piece

Mounting Type : Panel Mount

Frequency : 4565 Hz

Voltage : Universal 100415 V AC/DC (10%)

Control Type : Panel Mounted, Digital

Connectivity Type : RS485 Modbus

SCHNEIDER CONZERV EM6436H MULI-FUNCTION METER

SCHNEIDER CONZERV EM6436H MULI-FUNCTION METER

Minimum Order Quantity : 1 Piece

Mounting Type : Panel Mount

Frequency : 4565 Hz

Voltage : 57.7480V LN, 100830V LL AC (nominal)

Control Type : Digital

Connectivity Type : RS485 Modbus RTU

SCHNEIDER STB DDI 3725 BASIC DIGITAL INPUT MODULE

SCHNEIDER STB DDI 3725 BASIC DIGITAL INPUT MODULE

Minimum Order Quantity : 1 Piece

Mounting Type : DIN Rail

Frequency : 50/60 Hz

Voltage : 24V DC

Control Type : Digital Input

Connectivity Type : Module Bus, Standard Field Wiring