PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module
PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module
PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module
PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module
PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module
PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module
PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module
PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module

PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module

MOQ : 1 Piece

PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module Specification

  • Sensor Type
  • Analog or digital sensor inputs
  • IP Rating
  • IP20
  • Load Capacity
  • 50 mA (max)
  • Automation Grade
  • Industrial
  • Weight
  • Approx. 120 g
  • Frequency
  • DC signals
  • Features
  • Simple installation, maintenance free, galvanic isolation, short-circuit resistance, certified for hazardous areas (ATEX, IECEx), unidirectional
  • Control Type
  • Passive barrier
  • Mounting Type
  • 35 mm DIN rail (EN 50022)
  • Application
  • Intrinsic safety interface for hazardous areas (sensor signal conditioning, PLC/DCS input protection)
  • Remote Control
  • Yes
  • Connectivity Type
  • Screw terminals
  • Material
  • Aluminum enclosure, polyamide terminal block
  • Power
  • Passive (no power supply required)
  • Temperature
  • -20C to +60C (operating), -25C to +70C (storage)
  • Voltage
  • 28 V DC (max via zener diodes)
  • Channels
  • 2 Channels (double channel version)
  • Voltage Drop
  • Approx. 1.0 V
  • Color
  • Green
  • Model Number
  • Z757
  • Max Fuse Current
  • 50 mA
  • Dimensions (LxWxH)
  • 114 mm x 18 mm x 110 mm
  • Polarity
  • Unidirectional (one-way isolation)
 

PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module

PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module


The Z757 isolator is a versatile signal conditioning module from Pepperl+Fuchs, designed to provide galvanic isolation for both analog and digital signals.



Advanced Intrinsic Safety for Hazardous Environments

The Z757 Zener Barrier offers robust signal protection for your industrial control systems, making it an ideal choice for zones where intrinsic safety is paramount. Designed to protect analog or digital sensors working in potentially explosive atmospheres, this module isolates and conditions signals effectively, reducing risks associated with field instrumentation in hazardous areas.


Enhance System Reliability Without External Power

Benefit from completely passive operation-no external power supply is needed for the Z757 to function. Its maintenance-free design simplifies installation, enhancement, and ongoing safety compliance. The module's aluminum enclosure and polyamide terminal block offer durability and long-term reliability, while its simple screw terminal connections ensure fast, secure wiring.

FAQ's of PEPPERL+FUCHS Z757 Zener Barrier Signal conditioning module:


Q: How is the PEPPERL+FUCHS Z757 Zener Barrier installed?

A: The Z757 is designed for quick and easy installation onto a standard 35 mm DIN rail (EN 50022). Simply attach the unit to the rail in your control panel and connect input and output wiring using the screw terminals provided. No additional tools or power wiring are required.

Q: What types of signals can the Z757 Zener Barrier handle?

A: This module is suitable for DC signals from analog or digital sensor inputs. It serves as a protective interface for low-current signals, providing unidirectional (one-way) isolation for PLC or DCS input circuits in hazardous locations.

Q: When should I use the Z757 Zener Barrier in my automation system?

A: The Z757 should be used whenever you need to safely transmit sensor signals from hazardous areas to non-hazardous control equipment. It is particularly valuable in applications where intrinsic safety certification and reliable galvanic isolation are required.

Q: Where is the best location to install the Z757 in my system?

A: Install the Z757 on a DIN rail within an enclosure inside your control room or safe zone, but as close as practical to the point where wiring enters from the hazardous area. This placement minimizes potential risks and maintains signal integrity.

Q: What is the process for maintaining the Z757 Zener Barrier?

A: The unit is designed to be maintenance free. Routine visual inspection for secure mounting and tight terminal connections is recommended, but there are no user-serviceable parts or regular servicing requirements.

Q: How does the Z757 Zener Barrier protect my control equipment?

A: It provides short-circuit resistance and limits the voltage and current that can enter the hazardous area, thereby protecting PLC or DCS inputs and associated wiring from excess energy or surge conditions. Its certified design ensures compliance with ATEX and IECEx standards for hazardous environments.

Q: What benefits does the Z757 offer over powered isolators?

A: As a passive device, the Z757 requires no external power supply, which reduces complexity, cuts energy costs, and ensures operation even during power outages. Its simple design brings ease of installation, high reliability, and dependable signal protection for critical industrial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPER FUCHS Category

PEPPERL+FUCHS KFD2-CR-Ex1 30-200

PEPPERL+FUCHS KFD2-CR-Ex1 30-200

Minimum Order Quantity : 1 Piece

Material : Polycarbonate housing

Voltage : 20 V DC to 30 V DC

Automation Grade : Industrial Grade

Connectivity Type : Terminal connection

Features : SIL 2 (IEC 61508), galvanic isolation, pluggable terminals, LED indicator

Pepper Fuchs Kfd2-dwb-ex1d 49542s

Pepper Fuchs Kfd2-dwb-ex1d 49542s

Material : Plastic (Housing)

Voltage : 24 V DC Input

Automation Grade : Industrial

Connectivity Type : Terminal Block

Features : Intrinsic Safety Signal Isolation LED Indicators

PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER

PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER

Material : Plastic and Metal Components

Voltage : 24V DC

Automation Grade : Standard

Connectivity Type : Terminal Block

Features : Transformer Isolated Compact Design Reliable Performance

Pepper Fuchs Kfd2-sr2-ex2.w 132960

Pepper Fuchs Kfd2-sr2-ex2.w 132960

Material : Plastic Enclosure

Voltage : 2430 V DC

Automation Grade : Industrial

Connectivity Type : Wired

Features : Intrinsic Safety SpaceSaving Design



Back to top