PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER
PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER
PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER
PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER
PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER
PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER
PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER
PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER

PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER

PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER Specification

  • Phase
  • Single Phase
  • Weight
  • Approximately 100 grams
  • Warranty
  • 1 Year Manufacturer Warranty
  • Control Type
  • Passive
  • Application
  • Signal Isolation and Repeating in Hazardous Areas
  • Mounting Type
  • DIN Rail
  • Frequency
  • 50-60 Hz
  • Features
  • Transformer Isolated Compact Design Reliable Performance
  • Automation Grade
  • Standard
  • Connectivity Type
  • Terminal Block
  • Material
  • Plastic and Metal Components
  • Power
  • Low Power Consumption
  • Temperature
  • Operating Temperature: -20C to +60C
  • Voltage
  • 24V DC
 

PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER Trade Information

  • Supply Ability
  • 100 Per Month
  • Delivery Time
  • 7 Days
 

About PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER

PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER

PEPPERL+FUCHS KHD3-ICR/Ex 130 200 TRANSFORMER ISOLATED REPEATER

PEPPERL+FUCHS

TYPE : KHD3-ICR/Ex 130 200

TRANSFORMER ISOLATED REPEATER

K-SYSTEM

B02

PART.NO : 71035

[EEx ia] IIC BASEEFA NO.: Ex89C2003

LICENCE NUMBER : M3486

MAX.AMBIENT TEMPERATURE : 60C

Um = 250V TERMINALS/KLEMMEN 7,8,9,10

Un = 40V TERMINALS/KLEMMEN 7,8,9,10

U MAX OUT 28.0V TERMINALS/KLEMMEN 1,3

I MAX OUT 93mA TERMINALS/KLEMMEN 1,3

INPUT : 0-20mA

OUTPUT : 0-20mA

POWER SUPPLY : 20-35V DC


FAQs of PEPPERL+FUCHS KHD3-ICR/Ex 130200 TRANSFORMER ISOLATED REPEATER:


Q: What is the operating temperature range for PEPPERL+FUCHS KHD3-ICR/Ex 130200 Transformer Isolated Repeater?

A: The operating temperature range is -20C to +60C.

Q: What is the application of this product?

A: The application is signal isolation and repeating in hazardous areas.

Q: What is the connectivity type for this product?

A: The connectivity type is terminal block.

Q: What is the warranty period for PEPPERL+FUCHS KHD3-ICR/Ex 130200 Transformer Isolated Repeater?

A: The warranty period is 1 year Manufacturer Warranty.

Q: What is the voltage requirement for this product?

A: The voltage requirement is 24V DC.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPER FUCHS Category

PEPPERL+FUCHS KFD2-DW-Ex1D

PEPPERL+FUCHS KFD2-DW-Ex1D

Price Range 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Plastic / Electronic components

Cable Length : Dependent on sensor cable

Application : Intrinsically safe proximity sensors signal isolator for hazardous areas

Mounting Type : DIN Rail Mounting

PEPPERL+FUCHS KFD2-WAC-Ex1

PEPPERL+FUCHS KFD2-WAC-Ex1

Price Range 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Polycarbonate housing

Cable Length : Depends on installation

Application : Signal isolation and conversion in hazardous areas

Mounting Type : DIN rail

Pepperl Fuchs Kfd0-tr-ex1

Pepperl Fuchs Kfd0-tr-ex1

Minimum Order Quantity : 1 Piece

Material : FIBER

Cable Length : Depends on Installation

Application : Signal Isolation for Hazardous Areas

Mounting Type : 35 mm DIN Rail

PEPPERL+FUCHS KHD3-IPT Ex 116

PEPPERL+FUCHS KHD3-IPT Ex 116

Minimum Order Quantity : 1 Piece

Material : Plastic / Metal

Cable Length : Custom as per requirement

Application : Hazardous Area Terminal Box, Ex e junctions

Mounting Type : Wall / Surface Mount



Back to top