LEM LF 1006
LEM LF 1006
LEM LF 1006
LEM LF 1006
LEM LF 1006
LEM LF 1006

LEM LF 1006

MOQ : 1 Piece

LEM LF 1006 Specification

  • Load Capacity
  • 1000A Continuous
  • Frequency
  • DC to 50 kHz
  • Control Type
  • Current Control
  • Sensor Type
  • Closed Loop Hall Effect Current Transducer
  • Connectivity Type
  • PCB Mount / Solder Pins
  • Application
  • Current Measurement in Industrial and Energy Applications
  • Phase
  • Single / Three Phase
  • Features
  • High Accuracy, Fast Response, Galvanic Isolation
  • Mounting Type
  • Base / Panel Mount
  • Remote Control
  • Yes
  • Automation Grade
  • Automatic
  • Weight
  • Approx. 890 g
  • IP Rating
  • IP00
  • Material
  • FIBER
  • Power
  • 1000A
  • Temperature
  • -40C to +85C
  • Voltage
  • 4.3 kV (Isolation)
  • Output Signal
  • 4 V
  • Standards Compliance
  • EN 50178, IEC 61010-1
  • Dielectric Strength
  • 8 kV / 50 Hz / 1 min
  • Offset Current
  • <0.25 A
  • Response Time
  • <1 s
  • Supply Voltage
  • 15V DC
  • Aperture Size
  • 32 x 15 mm
  • Linearity
  • 1%
  • Accuracy
  • 0.9% of nominal value
 

LEM LF 1006 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 7 Days
  • Packaging Details
  • AS PER CUSTOMER REQUIREMENT
  • Main Export Market(s)
  • Australia, Asia, Central America, Middle East, Africa, Western Europe, South America, Eastern Europe, North America
  • Main Domestic Market
  • All India
 

About LEM LF 1006



Experience the efficiency of the LEM LF 1006-now with reduced pricing for a limited time! This hot-selling, top-ranking device is designed for noble precision, boasting an outstanding accuracy of 0.9% of nominal value and a rapid response time of less than 1 second. Buy for top-drawer performance in current measurement, with robust dielectric strength, 1000A continuous load capacity, and superior linearity. Compliance with international standards ensures high safety. Perfect for demanding industrial and energy applications, this automatic sensor delivers reliability through fiber construction and galvanic isolation. Available from leading distributors, exporters, and suppliers in Japan.

LEM LF 1006: Broad Suitability and Distinct Features

The LEM LF 1006 is engineered for both specific and general use in industrial and energy sectors, providing reliable current control for single and three-phase systems. Suitable for PCB mount or solder pin connectivity, its versatility extends to current measurements across automation processes. Other features, such as high galvanic isolation, rapid response, and closed loop Hall effect sensor technology, make it ideal for those seeking accuracy and safety in demanding applications.


Packaging, Supply, and Export Logistics of LEM LF 1006

Carefully packaged to ensure secure transportation, the LEM LF 1006 is delivered efficiently through streamlined logistics networks. Supply ability meets the demands of global markets, with prompt shipping to key export destinations. Main export markets include Asia, Europe, and North America, where reliability in delivered goods is paramount. Our partnerships with trusted logistics providers ensure that each device arrives in pristine condition, supporting your critical current measurement needs worldwide.


FAQ's of LEM LF 1006:


Q: How is the LEM LF 1006 commonly used in industrial applications?

A: The LEM LF 1006 is typically used for precise current measurement and control in automation, manufacturing, and energy management systems, ensuring safety and efficiency in single or three-phase systems.

Q: What benefits does the LEM LF 1006 offer compared to other current transducers?

A: It offers high accuracy (0.9%), fast response time (<1s), strong dielectric strength (8 kV), and superior galvanic isolation, making it suitable for high-performance and demanding environments.

Q: When should I choose the LEM LF 1006 for my project?

A: Choose the LEM LF 1006 when your project requires high-current measurement (up to 1000A), rapid response, precise linearity, and compliance with international safety standards such as EN 50178 and IEC 61010-1.

Q: Where can the LEM LF 1006 be mounted?

A: This transducer is designed for flexible installation, offering both base and panel mounting options to integrate easily into control panels or automated machinery.

Q: What is the process for integrating the LEM LF 1006 into an energy monitoring system?

A: The unit can be mounted onto a PCB or with solder pins, connected to the system's control circuitry, and calibrated according to the project's current rating and measurement parameters.

Q: Is the LEM LF 1006 suitable for general use or only for specialized applications?

A: The LEM LF 1006 is versatile, making it suitable for both general electrical current measurement uses and specialized industrial or energy sector tasks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in CURRENT SENSOR Category

ABB HBO 500

ABB HBO 500

Minimum Order Quantity : 1 Piece

Application : Main LT Panel Distribution

Connectivity Type : Hardwired

Temperature : 10C to +50C

Material : FIBER

Phase : Three Phase



Back to top