ICP COM RS-485 -7051D MODULE
ICP COM RS-485 -7051D MODULE
ICP COM RS-485 -7051D MODULE
ICP COM RS-485 -7051D MODULE
ICP COM RS-485 -7051D MODULE
ICP COM RS-485 -7051D MODULE
ICP COM RS-485 -7051D MODULE
ICP COM RS-485 -7051D MODULE

ICP COM RS-485 -7051D MODULE

MOQ : 1 Piece

ICP COM RS-485 -7051D MODULE Specification

  • Automation Grade
  • Automatic
  • Remote Control
  • Yes
  • Weight
  • ~130g
  • Connectivity Type
  • RS-485
  • Control Type
  • Digital I/O Module
  • Mounting Type
  • DIN Rail Mounting or Panel Mounting
  • Application
  • Remote digital input monitoring in industrial automation
  • IP Rating
  • IP30
  • Features
  • 8 channels digital input, LED indication, modbus compatible, surge & overvoltage protection
  • Material
  • ABS Fire-retardant Plastic
  • Power
  • 1.5 W (max)
  • Temperature
  • Operating: -25C to +75C, Storage: -30C to +80C
  • Voltage
  • +10 VDC ~ +30 VDC
  • Isolation Voltage
  • 3750 VDC (input to logic)
  • Power Consumption
  • 0.6W typical
  • Input Channels
  • 8
  • Surge Protection
  • 4 kV for RS-485
  • Protocol
  • Modbus RTU, DCON
  • LED Display
  • 8 LEDs for DI status
  • Communication Baud Rate
  • 1200 to 115200 bps
  • Input Type
  • Sink/Source, Dry/Wet contact
  • ESD Protection
  • 4 kV Contact
  • Dimensions
  • 123 mm x 72 mm x 35 mm
 

ICP COM RS-485 -7051D MODULE Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ICP COM RS-485 -7051D MODULE

ICP COM RS-485 -7051D MODULE


The -7051D is a RS-485 Active Star Wiring Hub. The unit has three independent RS-485 output channels, each with its own driver, which can transmit signals across 1200 m of cable on each channel.

The -7051D includes both Hub and Repeater functions, so each output channel can be connected to another hub. The isolation site of the -7051D is located in the input and output interface circuit. Hence, the -7051D is a three-way isolation module.

RS-485 Active Star Wiring Applications
Automatic Baud Rate detection, 300 115200 bps
ESD Protection for the RS-485 Data Line
3000 VDC Three Way Isolation Protection
Operating Temperature: -25 C +75 C
DIN-Rail or wall-mounting



Efficient Digital Input Monitoring

With 8 channels supporting both sink and source types, the RS-485-7051D module efficiently captures digital input signals in various industrial automation setups. LED indicators offer clear visual status, streamlining diagnostics and control.


Robust Connectivity and Protocol Support

Supporting RS-485 communication and protocols like Modbus RTU and DCON, the module allows seamless integration with existing systems for remote control and data acquisition. Surge and ESD protections ensure stable long-term operation.


Flexible Installation and Durability

With options for DIN-rail or panel mounting, a fire-retardant ABS enclosure, and an operating temperature range of -25C to +75C, the RS-485-7051D is suited for a wide range of indoor industrial environments requiring reliable automation.

FAQ's of ICP COM RS-485 -7051D MODULE:


Q: How do I connect and configure the ICP COM RS-485-7051D module for my system?

A: Connect the module to your RS-485 network using the designated terminals. Configuration can be managed via Modbus RTU or DCON protocol using compatible automation software. You may select between DIN rail or panel mounting for installation.

Q: What types of input signals does this module support?

A: The module supports digital inputs of both sink and source types, and is compatible with dry and wet contact signals, offering flexibility for different sensor or switch configurations.

Q: When should I use the RS-485-7051D's isolation and surge protection features?

A: The built-in 3750 VDC isolation and 4kV ESD/surge protection features are essential when operating in electrically noisy industrial environments. They safeguard the module and connected equipment from voltage spikes and interference.

Q: Where can I monitor the digital input status on the module?

A: You can view the status of each digital input channel directly through the 8 integrated LEDs on the module's front panel, providing real-time indication for troubleshooting or monitoring.

Q: What is the benefit of using Modbus RTU protocol with this module?

A: Modbus RTU protocol allows for standardized and reliable remote control and monitoring of the module, making it easy to integrate with SCADA systems, PLCs, or other industrial controllers.

Q: What is the recommended power supply specification for the RS-485-7051D?

A: Supply the module with a DC voltage ranging from +10 VDC to +30 VDC, with a maximum power consumption of 1.5 W, to ensure optimal and safe operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Industrial Automation Category

Ac/dc Drives (Vfd)

Ac/dc Drives (Vfd)

Price 15000 INR / Piece

Minimum Order Quantity : 10 Pieces

Phase : Singlephase or Threephase

Features : Energy efficient compact design userfriendly interface

Weight : Varies by model

Power : 0.37 kW to 250 kW

Conzerv Em 3360

Conzerv Em 3360

Phase : Threephase

Features : Digital display Parameter configuration

Weight : null

Power : null

SIEMENS 7MF0300-1FE01-5DM2-Z TRANSMITTER FOR PRESSURE

SIEMENS 7MF0300-1FE01-5DM2-Z TRANSMITTER FOR PRESSURE

Minimum Order Quantity : 1 Piece

Phase : Not Applicable (DC Supply)

Features : Robust, Compact design, High accuracy

Weight : Approx. 2 kg

Power : Loop Powered (2wire system)

GE PSU MULTILIN I/O RATINGS REFER TO MANUAL

GE PSU MULTILIN I/O RATINGS REFER TO MANUAL

Minimum Order Quantity : 1 Piece

Phase : Single Phase

Features : Wide Input Supply Range, I/O Configurability, Compact Size

Weight : Approx. 1.5 kg

Power : 40W Max



Back to top