FAL36100 (100A) CIRCUIT BREAKER Specification

  • Rated Short Circuit Making Current
  • Not specifically stated (typically equal or greater than breaking capacity)
  • Rated Short Circuit Breaking Current
  • 18 kA
  • Phase
  • Three Phase
  • Mechanical Life
  • 20,000 operations
  • Breaking Capacity
  • 18 kA @ 480V AC
  • Product Type
  • Molded Case Circuit Breaker (MCCB)
  • Installation Options
  • Panel Mounted
  • Function
  • Protection of electrical circuits against overloads and short circuits
  • Poles Number
  • 3
  • Rated Voltage
  • 600V AC
  • Rated Current
  • 100A
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • Thermal-Magnetic Trip Curve
  • Temperature Protection
  • Yes, via thermal protection
  • Weight
  • 3.5 kg (approx)
  • Color
  • Grey
  • Enclosure Rating
  • Open Type
  • Dimensions (H x W x D)
  • 152 mm x 105 mm x 67 mm (approx)
  • Terminal Type
  • Lug Terminals
  • Tripping Mechanism
  • Thermal-Magnetic
  • Accessories Compatibility
  • Yes, accepts auxiliary contacts and shunt trip
  • Operating Temperature Range
  • -25C to +40C
  • Frame Size
  • F Frame
  • Adjustment Range
  • Fixed (non-adjustable)
 

FAL36100 (100A) CIRCUIT BREAKER Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 500 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About FAL36100 (100A) CIRCUIT BREAKER

FAL36100 (100A) CIRCUIT BREAKER


Authentic FAL36100 Thermal-Magnetic Molded Case Circuit Breaker manufactured by Schneider Square D. Used in various applications. FY14015 is part of Schneider Square D's legacy line. Most of the legacy devices are obsolete but will be in service for many years.



High-Performance Circuit Protection

Equipped with thermal and magnetic trip curves, the FAL36100 circuit breaker offers advanced defense against both overloads and short circuits. Its 100A current rating and three-pole configuration make it highly suitable for demanding electrical systems in commercial and industrial applications.


Ease of Installation and Compatibility

The FAL36100 features lug-type terminals and a compact open-type F Frame, simplifying panel-mounted installations. It also supports various accessories including auxiliary contacts and shunt trip, enabling enhanced monitoring and remote control. This flexibility ensures smooth integration into new or retrofitted systems.


Reliable Operation Across Environments

Designed for performance in temperatures ranging from -25C to +40C, and featuring a mechanical life of up to 20,000 operations, the FAL36100 delivers enduring reliability. Its sturdy build and high breaking capacity provide unwavering circuit safety, making it suitable for numerous settings across India.

FAQ's of FAL36100 (100A) CIRCUIT BREAKER:


Q: How do I install the FAL36100 circuit breaker with lug terminals?

A: The FAL36100 circuit breaker is designed for panel mounting and comes with lug terminals for easy and secure wire connections. Ensure you follow the manufacturer's installation instructions, tightening all terminal connections to the specified torque and abiding by local electrical codes.

Q: What is the primary benefit of using the FAL36100's thermal-magnetic tripping mechanism?

A: The thermal-magnetic tripping mechanism protects circuits by instantly reacting to both prolonged overloads (thermal trip) and short circuits (magnetic trip), ensuring fast interruption of hazardous currents and improving overall safety and equipment reliability.

Q: When should the breaker's accessories, like auxiliary contacts and shunt trip, be added?

A: Accessories such as auxiliary contacts and shunt trip can be added during original installation or later as needed for enhanced remote monitoring and control. This flexibility allows for easy system upgrades without replacing the main breaker unit.

Q: Where can the FAL36100 circuit breaker be used considering its enclosure rating?

A: This circuit breaker is rated as Open Type, making it best suited for installation within electrical panels housed in indoor, protected environments where exposure to dust, moisture, or harsh conditions is minimal.

Q: What's the process for resetting the FAL36100 after a trip event?

A: After ensuring the fault condition (overload or short circuit) has been resolved, reset the breaker by firmly moving the operating handle to the OFF position, then switch it back to ON. Always adhere to safety protocols during this procedure.

Q: How does the fixed adjustment range impact the breaker's usage?

A: With a fixed (non-adjustable) 100A setting, the FAL36100 offers consistent protection calibrated to its rated current, reducing the risk of user error in field adjustments and ensuring dependable response to overcurrent conditions.

Q: What advantages does the FAL36100 provide in high-demand electrical environments?

A: With a breaking capacity of 18 kA @ 480V AC and a mechanical life of 20,000 operations, the FAL36100 delivers robust, long-lasting protection for critical circuits, supporting increased operational safety and reduced maintenance needs in busy facilities.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Circuit breaker Category

CUTLER HAMMER HJD 65K HJD3250F 250A 3POLE CIRCUIT BREAKER

CUTLER HAMMER HJD 65K HJD3250F 250A 3POLE CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Weight : 4.86 kg (approx)

Breaking Capacity : 65 kA @ 480V AC

Function : Circuit Protection

Temperature Protection : Yes, ThermalMagnetic trip

Mechanical Life : 10,000 operations

SQUARE D KH70A AL250KA 3P 70A CIRCUIT BREAKER

SQUARE D KH70A AL250KA 3P 70A CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Weight : 2.4 kg

Breaking Capacity : 25 kA @ 480V AC

Function : Circuit Protection (Thermal Magnetic)

Temperature Protection : Integrated Thermal Protection

Mechanical Life : 10,000 Operations

FPE NE233040 3 POLE AIR CIRCUIT BREAKER

FPE NE233040 3 POLE AIR CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Weight : Approx. 8 kg

Breaking Capacity : 50 kA

Function : Overcurrent protection, Short circuit & Overload protection

Temperature Protection : Builtin thermalmagnetic mechanism

Mechanical Life : 10,000 operations

CUTLER HAMMER HND 65K HND312T32W 1200A 3POLE CIRCUIT BREAKER

CUTLER HAMMER HND 65K HND312T32W 1200A 3POLE CIRCUIT BREAKER

Minimum Order Quantity : 1 Piece

Weight : Approximately 18 kg

Breaking Capacity : 65kA @ 480VAC

Function : Circuit Protection, Overload and Short Circuit Protection

Temperature Protection : Yes, thermalmagnetic protection

Mechanical Life : 10,000 Operations (Typical)