MOQ : 1 Piece

EASUN MIT 113 PROTECTION HEALTHY RELAY Specification

  • Mechanical Life
  • 10 million operations
  • Contact Form
  • 1 Change Over (SPDT)
  • Protect Feature
  • Overload, Phase Failure, Phase Sequence Protection
  • Coil Power
  • Approx. 1.5W
  • Contact Material
  • Silver Alloy
  • Dielectiric Strength
  • 2kV AC for 1 minute
  • Coil Voltage
  • 220V AC
  • Contact Resistance
  • <100 m
  • Ambient Temperature
  • -10C to +55C
  • Power Consumption
  • Less than 2VA
  • Working Temperature
  • -10C to +55C
  • Product Type
  • Protection Healthy Relay
  • Insulation Resistance
  • >100 M at 500V DC
  • Theory
  • Electromagnetic Relay
  • Usage
  • Industrial Automation, Electrical Panels, Motor Protection
  • Contact Load
  • 5A at 250V AC
  • Operate Time
  • <30 ms
  • Terminal Type
  • Screw Type
  • Rated Voltage
  • 220V AC
  • Supply Terminal
  • Input/Output Terminals
  • Size
  • Compact
  • Color
  • Light Grey
  • Dimension (L*W*H)
  • 80mm x 22.5mm x 100mm
  • Weight
  • Approx. 150g
  • Standards
  • IS/IEC 60255 Compliant
  • Reset Type
  • Automatic & Manual
  • Indication
  • LED for Relay Status
  • Humidity
  • Up to 95% RH non-condensing
  • Mounting Type
  • DIN Rail Mount
  • Number of Poles
  • Single Pole
  • Control Circuit Voltage
  • 220V AC
  • Frequency
  • 50 Hz
  • Application
  • Electrical Panels, Motor Protection Circuits, Industrial Automation
  • Response Time
  • <30 milliseconds
 

EASUN MIT 113 PROTECTION HEALTHY RELAY Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About EASUN MIT 113 PROTECTION HEALTHY RELAY

EASUN MIT 113 PROTECTION HEALTHY RELAY


The MIT 103/104/113/114 Protection unit consists of the following modules within its compact dimensions. Input Module ... Description Features Protection Phase and ground overcurrent with/without highset (50P, N/51P, N) Numerical, true RMS measurement ... Easun Reyrolle Limited.



Comprehensive Motor Protection

Equipped with advanced features such as overload, phase failure, and phase sequence protection, the EASUN MIT 113 relay safeguards critical equipment against electrical anomalies. Its quick response time reduces potential damages, making it a reliable component for industrial panels and automated systems.


Designed for Industrial Environments

This relay operates seamlessly under demanding conditions, tolerating ambient temperatures from -10C to +55C and humidity up to 95% RH (non-condensing). Its robust build and high insulation resistance ensure uninterrupted performance, while LED indications provide clear status monitoring.


Efficient DIN Rail Installation

Installation is straightforward with its DIN rail mount and screw-type terminals. The compact size and light grey finish make it an ideal choice for limited-space electrical panels, ensuring versatile application across multiple sectors including manufacturing, exporting, and service provision.

FAQ's of EASUN MIT 113 PROTECTION HEALTHY RELAY:


Q: How does the EASUN MIT 113 relay protect motors and electrical panels?

A: The relay incorporates overload, phase failure, and phase sequence protection to prevent equipment damage due to power abnormalities. Its rapid response and operate time, below 30 milliseconds, help minimize downtime and failure risks in industrial settings.

Q: What is the recommended usage environment for this relay?

A: It is suitable for industrial environments with ambient temperatures ranging from -10C to +55C and can withstand humidity up to 95% RH (non-condensing), making it reliable in challenging conditions typical of automation and electrical panels.

Q: When should the reset function be used, and what options are available?

A: The EASUN MIT 113 offers both automatic and manual reset. Use the manual reset for in-depth inspection after a fault, or rely on the automatic reset for continuous operations without manual intervention, according to your system's safety requirements.

Q: Where is the EASUN MIT 113 relay typically installed?

A: This relay is designed for DIN rail mounting inside electrical panels, control cabinets, and motor protection circuits. Its compact dimensions make it suitable for installations where space is limited.

Q: What is the process for wiring and installing the relay?

A: Wiring is completed using screw-type input/output terminals. Simply mount the relay on a DIN rail, connect the 220V AC control circuit, and ensure input/output connections are secure for reliable operation.

Q: What are the benefits of the LED relay status indication?

A: The integrated LED provides immediate visual feedback on the relay's operational status, allowing for quick diagnostics and reducing maintenance times for technicians.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

EASUN REYROLLE AR121T3/AR101 (AR_E4_09105) RELAY

EASUN REYROLLE AR121T3/AR101 (AR_E4_09105) RELAY

Minimum Order Quantity : 1 Piece

Usage : Protection and control in electrical switchgear

Product Type : Electromagnetic Relay

Color : Black/Grey

Protect Feature : Other, Overcurrent, phase, and earth fault protection

Operate Time : <25 ms

ABB REF615E D HBFDACADNBA BNN1XD PROTECTION RELAY

ABB REF615E D HBFDACADNBA BNN1XD PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Usage : Feeder protection relay for utility and industrial power distribution systems

Product Type : Numerical protection relay

Color : Grey/Black

Protect Feature : Other, Feeder protection, earth fault, overcurrent, distance, voltage, frequency

Operate Time : Typically less than 30 ms

ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)

ABB RET670 (SMALL SCREEN) PROTECTION RELAY (ONLY DISPLAY)

Minimum Order Quantity : 1 Piece

Usage : Protection relay display module for power systems

Product Type : Protection Relay Display (only display module)

Color : Grey front, black housing

Protect Feature : Other, Overcurrent, Differential, Transformer Protection (via relay unit)

Operate Time : Less than 20 ms (typical, depends on system integration)

MICOM P54531AC7M0750M Line Differential and Distance Protection Relay

MICOM P54531AC7M0750M Line Differential and Distance Protection Relay

Minimum Order Quantity : 1 Piece

Usage : Line Differential and Distance Protection for Power Systems

Product Type : Protection Relay

Color : Grey/Black

Protect Feature : Other, Overcurrent, Differential, Distance, and Backup Protection

Operate Time : 20 ms (typical)