ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)
ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)
ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)
ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)
ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)
ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)
ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)
ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)

ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)

MOQ : 1 Piece

ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY) Specification

  • Ambient Temperature
  • -25C to +70C
  • Contact Resistance
  • < 100 m
  • Power Consumption
  • < 40 VA
  • Mechanical Life
  • > 10,000 operations
  • Protect Feature
  • Overcurrent, Earth fault, Distance protection, Breaker failure
  • Contact Material
  • Silver Alloy
  • Contact Form
  • 2 change-over (DPDT)
  • Coil Power
  • Not Applicable (Display Module)
  • Coil Voltage
  • Not Applicable (Display Module)
  • Working Temperature
  • -25C to +55C
  • Dielectiric Strength
  • 2 kV, 50/60Hz, 1 min
  • Product Type
  • Digital Protection Relay Display only
  • Insulation Resistance
  • > 100 M at 500 VDC
  • Theory
  • Digital microprocessor-based relay
  • Usage
  • Protection relay in power systems
  • Contact Load
  • 5A at 250VAC / 30VDC
  • Operate Time
  • <30 ms
  • Terminal Type
  • Screw/Plug-in
  • Rated Voltage
  • 24-250 V DC/AC
  • Supply Terminal
  • Rear terminal block
  • Size
  • Standard Compact (Small Relay)
  • Color
  • Grey
  • Dimension (L*W*H)
  • 232 mm x 242 mm x 167 mm
  • Weight
  • Approximately 5 kg
  • Self-diagnostics
  • Continuous self-supervision
  • IP Protection Class
  • IP 54 Front
  • Disturbance Recorder
  • Integrated oscillographic recorder
  • Protocol Support
  • IEC 61850, Modbus, DNP3, IEC 60870-5-103
  • Display Type
  • LCD graphical display
  • Mounting Type
  • Flush/Panel Mounting
  • Communication Ports
  • RS232, RJ45 Ethernet, FO, USB
  • Event Recording
  • Yes, with time tagging
 

ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY) Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)

ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY)


REL670 provides protection of power lines with high sensitivity and low requirement on remote end communication. Measurements and setting of all six zones with six setting groups are made completely independent, which ensures high reliability for all types of lines.



Advanced Communication and Protocol Support

The ABB REL670 relay integrates seamlessly into diverse power systems, equipped with RS232, RJ45 Ethernet, fiber optic, and USB ports. Extensive protocol compatibility-covering IEC 61850, Modbus, DNP3, and IEC 60870-5-103-ensures efficient communication with existing substation automation frameworks and enhances interoperability for modern grid requirements.


Robust Protection and Event Recording

This relay is engineered to provide comprehensive protection functions such as overcurrent, earth fault, distance, and breaker failure. Integrated event recording with time tagging and an oscillographic disturbance recorder deliver precise diagnostics and enable in-depth analysis of electrical disturbances, facilitating rapid response to system anomalies and incidents.


High Durability and Flexible Installation

Built with durability in mind, the REL670 features a compact, robust design with over 10,000 mechanical operations and IP54-rated front protection. It supports flush or panel mounting and offers both screw and plug-in terminals for reliable connections. Its wide operating temperature range and high insulation resistance make it ideal for challenging substation environments.

FAQ's of ABB REL670 SMALL PROTECTION RELAY (ONLY DISPLAY):


Q: How does the ABB REL670 Small Protection Relay enhance system reliability in power networks?

A: The ABB REL670 provides advanced protection features such as overcurrent, earth fault, distance protection, and breaker failure detection. Its fast operate time (less than 30 ms), continuous self-supervision, and integrated event and disturbance recorders contribute to quick fault isolation and system stability, reducing downtime in power networks.

Q: What is the process for installing the ABB REL670 relay?

A: Installation involves flush or panel mounting using standardized dimensions and securing the device with the specified rear terminal block for power and signal connections. Both screw and plug-in terminal types are supported. The relay should be connected per the provided instructions and configured through supported communication ports using standard protocols.

Q: When should the integrated disturbance recorder function be used?

A: The integrated oscillographic disturbance recorder should be utilized whenever a fault or event occurs in the power system. It automatically captures relevant waveform data and time tags events, supporting in-depth post-event analysis and facilitating precise restoration and maintenance actions.

Q: Where can this relay be deployed within a power system?

A: The ABB REL670 is suitable for deployment at various protection points within substations or distribution panels due to its flush/panel mounting flexibility, robust environmental tolerance, and IP54-rated front protection. Its compact design and versatile communication options allow integration in diverse utility and industrial settings.

Q: What are the main benefits of using a relay with multiple communication protocols like IEC 61850 and Modbus?

A: By supporting a wide spectrum of protocols, the relay ensures interoperability with different SCADA and automation platforms, streamlining integration and future expansion. This minimizes system compatibility issues, promotes flexibility, and helps utilities maintain control over increasingly complex power grids.

Q: How does the self-diagnostic feature improve operational safety?

A: Continuous self-supervision enables the relay to monitor its own operational health. If any internal issue is detected, it can signal maintenance personnel immediately, allowing for preemptive intervention and minimizing the risk of undetected faults within the protection system.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

Instantaneously  Under Voltage  Vag21zg8382g(M)

Instantaneously Under Voltage Vag21zg8382g(M)

Price Range 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Contact Form : SPDT

Theory : Other , Electromagnetic Relay

Contact Load : Other, 5A 250VAC

Supply Terminal : Single phase

ABB REC650 PROTECTION RELAY (ONLY DISPLAY)

ABB REC650 PROTECTION RELAY (ONLY DISPLAY)

Minimum Order Quantity : 1 Piece

Contact Form : NO/NC (modular outputs)

Theory : Other , Microprocessorbased relay

Contact Load : Other, 10 A / 250 V AC, 8 A / 24 V DC (relay outputs)

Supply Terminal : Rear connection, dedicated power terminals

SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY

SIEMENS 7UM6221-2EB92-0AC0/FF (BF1110052222) GENERATOR PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Contact Form : Form C (changeover contact)

Theory : Other , Microprocessor based digital relay

Contact Load : Other, DC side: 30 V / 6 A; AC side: 250 V / 8 A (resistive load)

Supply Terminal : Rear terminal block

LEADSHINE EM32DX-A2 PLC

LEADSHINE EM32DX-A2 PLC

Minimum Order Quantity : 1 Piece

Contact Form : SPDT (Single Pole Double Throw)

Theory : Other , Sequential Control

Contact Load : Other, Relay Output: 2A at 30VDC / 250VAC

Supply Terminal : 24V DC Power Input



Back to top