ABB REG670AISCWO16I0828 PROTECTION RELAY
ABB REG670AISCWO16I0828 PROTECTION RELAY
ABB REG670AISCWO16I0828 PROTECTION RELAY
ABB REG670AISCWO16I0828 PROTECTION RELAY
ABB REG670AISCWO16I0828 PROTECTION RELAY
ABB REG670AISCWO16I0828 PROTECTION RELAY
ABB REG670AISCWO16I0828 PROTECTION RELAY
ABB REG670AISCWO16I0828 PROTECTION RELAY

ABB REG670AISCWO16I0828 PROTECTION RELAY

MOQ : 1 Ampere

ABB REG670AISCWO16I0828 PROTECTION RELAY Specification

  • Coil Voltage
  • Not applicable (solid-state relay)
  • Dielectiric Strength
  • 2 kV, 50/60 Hz, 1 min
  • Power Consumption
  • Max. 60 VA
  • Working Temperature
  • -25C to +70C
  • Contact Resistance
  • <100 m
  • Contact Material
  • AgNi (Silver Nickel Alloy)
  • Ambient Temperature
  • -5C to +55C
  • Coil Power
  • Not applicable (solid-state relay)
  • Contact Form
  • Form A (SPST), Form C (SPDT)
  • Protect Feature
  • Multiple protection functions (distance, line differential, transformer, busbar protection, etc.)
  • Mechanical Life
  • >10 million operations
  • Product Type
  • Protection Relay
  • Insulation Resistance
  • >100 M @ 500 V DC
  • Theory
  • Microprocessor-based digital relay
  • Usage
  • Protection and control in power systems
  • Contact Load
  • 10 A at 250 V AC/30 V DC
  • Operate Time
  • <15 ms
  • Terminal Type
  • Screw terminal
  • Rated Voltage
  • 110-250 V DC, 100-240 V AC
  • Supply Terminal
  • Rear terminal connection
  • Size
  • Standard 19-inch rack; 3U
  • Color
  • Grey
  • Dimension (L*W*H)
  • 483 x 132 x 220 mm (approx.)
  • Weight
  • Approx. 6 kg
 
 

About ABB REG670AISCWO16I0828 PROTECTION RELAY

ABB REG670AISCWO16I0828 PROTECTION RELAY

REG670 IED (Intelligent Electronic Device) provides protection and monitoring for generators, prime movers, and step-up transformers in hydro, pump-storage, gas, combined cycle, steam, and cogeneration stations. With excellent performance, flexibility, and scalability it fulfills the demanding requirements, in every corner of the world, for both new installations and retrofits.

Based on Hitachi Energys extensive experience, REG670 takes generator protection to a new performance level. Up to 24 analog inputs permit integration of main and back-up protection in one IED. Alternatively, additional objects, such as transformers, can be included in the generator protection scope. This enables full duplication of the protection in main one and main two. These features allow a reduction of the number of IEDs needed to protect the entire generating station, increasing availability at the same time. This, in turn, simplifies the installation and reduces its lifecycle cost as related to commissioning, maintenance, and spare parts. REG670 functionality also incorporates intelligent fault criteria, ensuring unrivaled selectivity and sensitivity.



Comprehensive Protection and Advanced Control

The REG670AISCWO16I0828 relay brings together differential, overcurrent, ground fault, distance, under/over voltage, and frequency protections, making it suitable for safeguarding generators, transformers, and busbars. Intuitive push-button controls and a navigation-enabled LCD display offer enhanced usability for operators managing complex power systems.


Flexible Configuration and Easy Integration

Engineered for adaptability, this relay provides 16 digital inputs and 28 outputs, with versatile connection options through screw-type rear terminals. Communication is streamlined via Ethernet RJ-45, RS-232, USB, and IEC 61850, ensuring efficient data exchange and system compatibility for both new and legacy power infrastructures.


Reliable Operation in Demanding Environments

Withstanding temperatures from -25C to +70C and offering >10 million mechanical operations, the REG670AISCWO16I0828 is built for longevity. Its IP20-rated enclosure and high dielectric and insulation strengths guarantee consistent performance in varied conditions, ensuring your power systems remain secure and stable.

FAQs of ABB REG670AISCWO16I0828 PROTECTION RELAY:


Q: How can the ABB REG670AISCWO16I0828 protection relay be mounted?

A: This relay offers flexible installation options and is designed for both panel mounting and standard 19-inch rack setups, accommodating diverse control room or substation requirements.

Q: What communication interfaces are available for this relay?

A: The REG670AISCWO16I0828 features multiple communication ports, including Ethernet RJ-45, RS-232, USB, and full IEC 61850 protocol support, ensuring robust data communication with supervisory and control systems.

Q: When should the event and disturbance record memories be used?

A: Event record memory (up to 500 records) is useful for tracking system events and faults, while the disturbance record memory (for up to 100 faults) provides detailed data after protection operations, assisting in diagnostics and post-event analysis.

Q: Where is this protection relay typically applied?

A: It is ideal for generator, transformer, and busbar protection applications in power stations, substations, and industrial power systems, where reliable and multi-functional protection is essential.

Q: What is the process for upgrading the firmware on this relay?

A: Firmware upgrades are straightforward and can be performed via the USB or Ethernet ports using ABBs dedicated software tools to keep the relays functions current with the latest enhancements.

Q: How does the relay benefit power system protection and control?

A: By integrating multifaceted protection features and fast operate times (<15 ms), the relay enhances system reliability, mitigates fault impacts, and ensures safer, uninterrupted power supply.

Q: What are the environmental and operational limits for this relay?

A: The REG670AISCWO16I0828 is designed to operate in ambient temperatures from -5C to +55C and can withstand working temperatures from -25C to +70C, accommodating diverse climatic and operational conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Relay Category

ABB REF615 RELAY

ABB REF615 RELAY

Minimum Order Quantity : 1 Piece

TRANSFORMER PROTACTION RELAY TR-7570

TRANSFORMER PROTACTION RELAY TR-7570

Price Range 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

HIMAP EI0010012 RELAY

HIMAP EI0010012 RELAY

Minimum Order Quantity : 1 Piece



Back to top